Loading...
PERMIT DOCUMENTS TROY—MOSES PANTON Florida Architect AR94097 14311 Biscayne Blvd.#4323—Miami,FL 33161 786.985.9156 I www.troymoses.com I troymoses@gmail.com July 28, 2017 City of Boynton Beach Building Department Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach, FL 33435 Permit No. 1700000900 OPENING INSPECTIONS FOR 400 VILLA CIRCLE—BUILDING NO.4 This letter serves to notify that my representative or I have inspected the installation every exterior window and sliding glass door for the above referenced project and confirm that the new window and door products have been installed as per the manufacturer's specifications and installation details. To the best of my knowledge all work was done in compliance with the 2014 FBC and all applicable local codes. The product approvals are as follows: Horizontal Sliding Window: CGI Windows & Doors, NOA# 15-0929.13 Series "Sentinel 120" Single Hung: CGI Windows & Doors, NOA# 15-0512.10 Series "Sentinel 110" Sliding Glass Door: CGI Windows & Doors, NOA# 15-0619.06 Series "Sentinel 150" New windows and sliding glass doors were properly sealed against water infiltration with Sikaflex sealant on the exterior, and Loctite Polyseamseal on the interior per manufacturer specifications. 2nd and 3rd floor windows with sills less than 36" high are equipped with ASTM F 2090-10 approved window opening control devices not to allow the passage of a 4" sphere. Please feel free to contact project manager, Carlos De Los Santos,via email at cdts01Cu@smail.com or phone at 954.446.3810 if there are any further questions or concerns. • Respectfully yours, Troy-Moses Panton, RA r , • AC ��� D roti • wistC:jj 0 , . 4: / / email:file 20( 170�Zf sH,) ,,, Try0„. INSPECTION LOG MirabellaVilla 2925 S. Federal Hwy ° 400 Villa Circle Boynton Beach o Building # 04 Permit # 1700000900 UNIT# Date: Passed Failed Comments Inspector 401 0 /zz-/r 7 t — ids 402 o y it/r7 ✓ -- /SS403 ✓ -- c�h5 404 ✓ _ eiK 405 012z47 i/' -- INC406 /zz/il ✓ _ ac 407 oc urn �' - 15 408 ® v - eh5 409 fl ✓ — 69.46 410 oc�/zz/, 17 _ Ci'/Y5 411 oci/ziA 7 ✓ 6946 412 oq/zz/f7 r/ _ e.6CS 413 09/ 22/7 I/ _ a:, 414 c2ct/z z//7 c1' — 6��d 5 415 oyl zz/7 V — ess 416 aU/Z z/ ? c/ 6®1.43 417 of//2z/7 _✓ /41C418 oil tz r-7 ✓ _ e4s 419 0Lilt z ri L14-5 �Av. 1 , ti , ir 420 °Li/tz./7 r/ r'1P�izo?........a 421 ocW/zz r7 �' .P cep 422 ocr/22 / 7 -- ,Ifi �- _ �' ���- 423 oyt it I-7 ✓ — �/��!a°, i` 4s'� 424 o c/'/zz /r ✓ / , ' (- • =.S •.......- :...... RE . TROY-MOSES PANTON FILE Florida Architect AR94097 Copy 14311 Biscayne Blvd.44323—Miami,FL 33161 786.985.9156 I www.troymoses.com I troymoses@gmail.com August 21, 2017 City of Boynton Beach Building Department Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach,FL 33435 This letter serves to notify that my representative or I have inspected the installation every exterior window and sliding glass door for the permits listed below Permit No.1700000890(Mirabella Villa Bldg.1101) Permit No. 1700000899(Mirabella Villa Bldg.#02) Permit No. 1700000894(Mirabella Villa Bldg.#03) Permit No.1700000900(Mirabella Villa Bldg.#04) Permit No. 1700000892(Mirabella Villa Bldg.#05) Permit No.1700000893(Mirabella Villa Bldg.#06) Permit No. 1700000895(Mirabella Villa Bldg.#07) Permit No. 1700000901(Mirabella Villa Bldg.#08) Permit No. 1700000897(Mirabella Villa Bldg.#10) Permit No. 1700000902(Mirabella Villa Bldg.#11) Permit No. 1700000891(Mirabella Villa Bldg.#12) Permit No. 1700000898(Mirabella Villa Bldg.#13) Please feel free to contact project manager, Carlos De Los Santos,via email at cd1s01@gmail.com or phone at 954.446.3810 if there are any further questions or concerns. Respectfully yours, Troy-Moses Panton, RA InCom- * /.cc email:file _ • ••n c 1 17(0f z �Y. FILE COPY rt( °: CITY OF BOYNTON BEACH 6 .\.,;,(k, r DEVELOPMENT DEPARTMENT I BUILDING DIVISION el'i`o": 33425. 561 742-6350•Pas 742-6357 o N 100 East Boynton Beach Boulevard•Boynton Beach,RL ( ) • Special Inspector Application In accordance with Section 110 of the Oty of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary inspections, as outlined In Section 110 of the Florida Building Code. The Special/Threshold inspector shall maintain progress inspection reports onsite during construction, submit to the Jurisdiction on a weekly basis Inspections reports, and provide a Certificate of Compliance after a I I work Is complete to the Building Official before the final Inspection as per Section 110 of the Florida BuildingCode. Note: The Building Official shall determine whichcdiscretionary Inspections are to be delegated. Name of Project: / /i tr (�pr Permit#_ Date: Z�22(7 Project Address: 7� �� FraTIZi41_ liW y Zip Code: Legal Description: PCN:08-43-45-_ A. Mandatory inspections Type: 1) Stem wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. — DYES-ONO- 2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. DYES ONO 3) Structural Steel,connections,welding,bolts and anchor rods. DYES ONO 4) Smoke Control Systems. OYES ONO 5) Threshold Building(f.s.section 553.79(5)) OYES ONO B.Discretionary Inspection Type:Per Building Official 1) Buildings and structures of unusual design or methods of construction. DVS ONO • Windows and doors BYES ONO • Structural and fire resistance Integrity' • OYES ONO 2) Buildings of Type I construction. OYES ONO 3) Major structural alterations OYES ONO 4) Where the concrete design is based on compressive strength In excess of 3,000 pounds per square inch. OYES ONO 5) Buildings with an area greater than 20,000 square feet. DYES ONO 6) For buildings more than 2 stories in height. OYES ONO 7) Pile driving. DYES ONO 8) Private Provider, structural 0Electrical ❑Plumbing °Mechanical OYES ONO 9) Other, DYES ONO C. Mandatory Documeration: 1) Inspection schedule stating the specific Inspection that will be made and at what phase of construction must be submitted with this application. 2) Progress report/Irtspectlon reports during construction. 3) Certificate of Compliance shall be submitted prior to the cheduting of the final building Inspectio / fir VA reS — owners Printed name: /fc/ ,S, 4c✓7401,_Signature: AQ r';,,,,, Permit Holders Printed Name: Signature: O`r••QI�TL� :' ' Penult Holders licensed: /^�' (4 ✓We •- Roc�_(UO � l) LL• l ' '1_.r` A Special Building Ins f ( rv(a: �.� O:W ,l, - .CC pec g pector Printed Name: tore: . !P'� •� :1 i. IV Architect and/or O lken -.y/ rr Special Inspector Signature: "Wrier - �j �•'. �� °'� �[ 't' SpedaI inspector Address: a .u.sic iv iCVa-q3y3 "mu 01 ,/ •• V '‘�r-I•_•i State of Florida Registration d: • /sic 8 �pE .sem y�• �• Original SeaI/Altai Date PhoneJL;/'1_7�F""_. Email: �9( .a//(•(� C�ct,iliL.out *Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall,floor or partition will be made for electrical,gas,mechanical,plumbing and communication conduits, pipes and systems. Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies. C:1Usets1Klae ndortS4Documents12010 Special Inspector Appll®tlon.docx