Loading...
PERMIT DOCUMENTS 1 /7 0vf 41 FLO A ENGINEERING & TESTING, INC. Phone: (866)781-6889 •Fas: (866) 784-8550 wr„v.floridaengineeringandtesting.com 250 S.W. 13th Avenue Pompano Beach, FL 33069 August 7, 2017 Job Order No.: 17-2602 Permit No.: Ron Bell Roofing 1020 SW 10th Street Delray Beach, Florida 33444 RE: ROOF INSPECTIONS Wryals Residence - Sloped Tile Roof 1467 SW 25th Place - Unit C; Boynton Beach, FL Dear Sir or Madam: Per your request, Florida Engineering & Testing Inc. has conducted a visual as-built inspection on August 3, 2017 to verify the re-roofing workmanship and materials used. Our inspection was performed to the minimum standards of the Florida Product Approval # FL7804-R9, RAS-120, and the Florida Building Code, latest. Our field inspection procedure consisted of selecting one area in each roof zone as a representative sample of the whole. The contractor removed roofing layers to expose the underlayment lapping, and back nailing in the field, perimeter and corner areas of the roof. The following is a summary of our observations: Sheathing Inspection The sheathing material was observed to be a 5/8" plywood sheathing secured at panel edges with 8d common nails at 6" o.c. and at 6"o.c. at intermediate supports. Underlayment Inspection The underlayment sheet was observed to be a Boral TileSeal HT underlayment sheet fully self- adhered directly to the plywood deck. The head/side laps were observed to be a minimum of 3" and no end laps were observed. No bubbles, blisters, or fish mouths were observed and all laps were observed to be fully adhered and well bonded. The underlayment sheet was observed to be backnailed at a maximum of 12" o.c. The drip edges were observed to be attached at a maximum of every 4" o.c. with ring shank nails with a minimum 6"overlap at seams. We were able to determine to the best of our ability and with a reasonable degree of certainty, that the sheathing and underlayment sheet installations were performed in accordance with the above referenced standards. ieff Qr, Quality 2, taL�insurance Page 2,August 7,2017,Job Order# 17-2602 Ron Bell Roofing ;97A Wryals Residence-Sloped Tile Roof 1467 SW 251h Avenue- Unit C; Boynton Beach, FL: Florida Engineering & Testing, Inc. appreciates the opportunity to be of service to you at this phase of your project. Should you have questions or comments, please feel free to contact us at your earliest convenience. Sincerely, 0\011111/0 Mark A. Mesiano, P.E. '�; No Neo e Florida Engineering & Testi-4111c. 48202 -c Florida Reg. No. 48202 0 ; 87- * ; O Certificate of Authorization 1FD69p AOR % * ,��zpNIL ENO t " i ? -a&ay FLO - i A ENGINEERING & TESTING, INC. • Phone: (866)781-6889 •Fas: (866) 784-8550 www.floridaengineeringandtesting.com 250 S.W. 13th Avenue Pompano Beach,FL 33069 August 28, 2017 Job Order No.: 17-2890 Permit No.: 17-2624 Roil Bell Roofing, Inc. 1020 S.W. 10th Street Delray Beach, Florida 33444 RE: TAS-106 TILE UPLIFT TESTS Proposed Roof Wryals Residence 1467 S.W. 251h Place Boca Raton, Florida Dear Sir or Madam: In accordance with your authorization, Florida Engineering & Testing Inc., has performed Tile Uplift Testing in compliance with Testing Application Standards TAS-106 and the Florida Building Code High Velocity Hurricane Zone on August 24, 2017, at the above referenced project. The purpose of our inspection was to determine the uplift capacity of the roof tiles for the proposed addition at the above referenced project. This inspection does not include the roof tiles for the rest of the existing structure. The subject roof consisted of Concrete flat tile foam set. The pitch of the subject roof is 4/12. Our field engineer's representative visited the site and conducted forty-four (44) uplift tests on the roof tiles. All tests were performed according to the Florida Building Code High Velocity Hurricane Zone and protocol TAS-106 using an Intercomp scale model CS200. The following is a summary of results: Field Test Results Test Number Test Location Field Uplift Pull Test Test Result 1 - 4 Corner See Attached Diagram 35 ± 5 pounds Passed _ 5 - 19 Perimeter See Attached Diagram 35 ± 5 pounds Passed 20 - 33 Field See Attached Diagram 35 ± 5 pounds Passed 34 - 44 Ridge See Attached Diagram 35 ± 5 pounds Passed the IfrQ Quality t a 4 A V.9ssurance 'at CLQ Page 2 August 28,2017 Job Order No. 17-2890 FLO A Ron Bell Roofing, Inc. Wryals Residence 1467 S.W. 25th Place Boca Raton, Florida: All test results were found to be in compliance with TAS-106 and the Florida Building Code (see attached field sketch). The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a final roof inspection. A final roof inspection must be conducted by the building official for approval. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. Florida Engineering & Testing, Inc. (FE&T) is an independent third party providing un- biased testing information and results. FE&T is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Florida Engineering & Testing, Inc., appreciates the opportunity to be of service to you at this phase of your project. If you have any questions or comments, please give us a call. We would be pleased to help in any way we can. It has been a pleasure working with you and look forward to doing so again in the near future. Sincerely, t \\\\A011111 /I P FS+14 a7' No.48202 \O _ * * = Mark A. Mesitrjo, P.E. * , Florida Engig� ng W sAfig, j4 '. Florida Reg.�si��4'82,1ThRtpP.•;.. Certificate of Afrtgr, i 1\$ —023 t /7- 0; 60 I 0711 c)� V •— Vi ct o u ell CD 8 .0 b o A E• o d O� O. . Z cu IIn w u et N p Ii E 3 c _ CI ova L ^o o, r_ u _ a In U. L U. 7N O f7N u it M M u U u x x E L U. C C 6 411 1l3 x '. 1E O o TL • i 40 tat lea 4 r� i^ f I la—)