17-056728"10" J 2'- 4" EXHAUST FAN SWITCH---__� PANEL 18" 1'-6" 66" 5'-6" J s HOOD #1 HEAT ISEI 4 24" L 24" EXHAUST EXHAUST 1 48„ 01 -1' 4'-p„ 41 49" 4'-1" PLAN VIEW SCALE: 1/2" = 1'-0" FAN SWITCH PANEL EX COLLAR 8" X 8" HOOD #1 pill 4'-p„ -_ 0 (,- O. ELECTRIC - WAFFLE 0 TABLETOP FRYER PRESS ,- 2-2-X22' 11 717' HAZARD ;AREA 21"X16 HOOD TEMPERATURE SENSOR 3" INTEGRAL AIR SPACE ON HOOD FOR 0" CLEARANCE TO LIMITED COMBUSTIBLE SURFACES 30 18" 2,_6»X. 1,_6» U.L. CLASSIFIED BAFFLE FILTERS HOOD #1 FINISHED S/S BACK GREASE TROUGH WITH CONTAINER PER NFPA 96 28" 6" MAX UNDE H. 2» 6" MIN '-4 -11 FRONT ELEVATION AIR BALANCE SCHEDULE EX CFM SUPPLY CFM DIFFERENCE AIR EXHAUSTED FROM HOODS 540 AIR SUPPLIED TO HOODS 432 X FIRE RATED CEILING TOTAL AIR VOLUME 540 1432 -108 HVAC SYSTEM OF BUILDING TO PROVIDE MORE THAN 108 CFM TO INSURE OVERALL BUILDING BALANCE IS POSITIVE. KITCHEN TO BE NEGATIVE WITH RESPECT TO ADJACENT AREAS NOT TO EXCEEED -0.02" WATER COLUMN 66" 5,-6" G EFT SIDE ELEVATION HVAC DESIGN CRITERIA EXHAUST COLLAR YES NO FIRE DAMPER X SMOKE DAMPER X FIRE RATED CEILING X DUCT SMOKE DETECTOR X DUCT WRAP X FIRE RATED ENCLOSURE X SCALE: 1/2" = 1'-0" STXB-10 EXHAUST FAN DETAIL N.T.S. 79" 6$„ 0 0 94„ 0 0 15T-6" EXHAUST FAN TD -250 EXHAUST FAN DETAIL HOOD SCHEDULE HOOD EXHAUST COLLAR COLLAR AREA GREASE DUCT VELOCITY FILTERS FILTER AREA VELOCITY THRU EX FILTERS LIGHTS UTILITY CABINET SWITCHES # MFG. MODEL LENGTH TYPE MATERIAL WGT (LBS) QTY SIZE S.P. CFM (SQFT) (FPM) TYPE QTY SIZE (SQFT) (FPM) QTY TYPE SIZE LOCATION HOOD LIGHT 1 HOOD DEPOT NDFWM-0482830000 4'-0" TYPE 1 430 S/S EXPOSED 100 1 8 x 8 0.384" 540 0.44 1215 TYPE VI 3 16 x 16 6.27 86 I- -No T NO N/A N/A N/A LEFT LEFT 0 16 x 20 FAN SCHEDULE HOOD # LABEL MFG. MODEL CFM S.P. HP VOLTAGE PHASE RPM AMPS WGT (LBS) 1 EF -1 JENCO STXB-10 540 0.85 0.25 115V 1 PH 1502 5.8 124 1 SF -1 HOOD DEPOT TD -250 432 0.5 0.25 115V 1 PH 3200 5.8 19.8 REQUIREMENTS BY ELECTRICAL CONTRACTOR 1. WIRE EACH FAN CIRCUIT FROM CIRCUIT BREAKER TO LINE SIDE OF CONTACTOR IN CONTROL PANEL. 2. WIRE EACH FAN FROM LOAD SIDE OF CONTACTOR IN CONTROL PANEL TO DISCONNECT SWITCHES ON FAN. DISCONNECT SWITCHES PROVIDED ON FANS. 3. WIRE A 120V 20 AMP CONTROL CIRCUIT TO TERMINALS L AND N IN CONTROL PANEL. 4. IF THERE IS NO FIRE ALARM PRESENT IN THE BUILDING THEN WIRE FROM CONTROL PANEL TERMINALS NO AND N TO HORN/STROBE DEVICE IN KITCHEN. 120V HORN/STROBE DEVICE TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 5. WIRE FROM CONTROL PANEL TERMINALS NO AND N TO SHUNT TRIP BREAKERS IN CIRCUIT BREAKER PANEL. ALL ELECTRICAL OUTLETS AND APPLIANCES UNDER THE HOOD NEED TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION. SHUNT TRIP BREAKERS PROVIDED BY ELECTRICAL CONTRACTOR. 6. FIRE ALARM CONNECTIONS -IF A FIRE ALARM IS PRESENT IT NEEDS TO BE CONNECTED TO THE SPARE MICROSWITCH (DRY CONTACTS). WIRES FOR MICROSWITCH ARE LOCATED IN THE 190 JBOX NEAR THE FIRE SYSTEM CONTROL HEAD. IF A BUILDING FIRE ALARM IS PRESENT A HORN/STROBE DEVICE IS NOT REQUIRED. 7. HEAT SENSORS NEED TO BE WIRED FROM EACH HOOD TO CORRESPONDING TERMINAL BLOCKS IN CONTROL PANEL. 8. WHEN THERE IS NOT A FIRE CABINET BUILT INTO OUR HOOD THE MICRO SWITCH MUST BE WIRED FROM THE FIRE SYSTEM CONTROL HEAD TO OUR CONTROL PANEL. THE COM WIRE (BLUE) GOES TO TERMINAL C IN OUR PANEL, THE NORMALLY CLOSED WIRE (YELLOW) GOES TO TERMINAL NC IN OUR PANEL AND THE NORMALLY OPEN WIRE (BROWN) GOES TO TERMINAL NO IN CONTROL PANEL. 9. FIRE SYSTEMS IN TYPE I HOODS THAT SHARE A FIRE HAZARD AREA MUST ACTIVATE SIMULTANEOUSLY. FIELD WIRING - - - - - GENERAL NOTES: A. ELECTRICAL INSTALLER IS FACTORY WIRING TOP OF H00 REQUIRED TO PROVIDE AND TEMPERATURE SENSOR TO BE PLACED IN THE y (SEE AM) (SEECONDIAGR lig---- GREASE EXHAUST HOOD TO ACTIVATE THE INSTALL APPROVED MEANS OF NOTE: DISCONNECT DASHED LINES REPRESENT FIELD WIRING B. ALL OUTPUTS FROM TERMINAL ® BLOCKS ARE 120V ONLY 00000000 mom 70 ALL IN CONTROL PANEL 1UA FAN #1 15V 1 PHASE 0.25 HP 5.8 AMPS t_ -t - - - - - - - - - - - - - - - - - - - -I A, SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN AREA, B. FIRE MODE REQUIRES EXHAUST FAN TO OPERATE CONTINUALLY AND STOP SUPPLY FAN, C. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED, D. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANYONE OF THE SYSTEMS, E. GAS AND ELECTRICAL EQUIPMENT AND OUTLETS SERVED BY THE HOOD SHALL BE DEACTIVATED IN THE EVENT OF A FIRE SYSTEM ACTUATION PER NFPA 96 10.4 F. ACTUATION OF THE FIRE SYSTEM SHALL SIGNAL THE ALARM SYSTEM SERVING THE AREA OCCUPIED BY THE HOOD PER NFPA96 10.6 MODEL "NDFWM" EXHAUST HOODS ARE U.L. LISTED FOR USE OVER COMMERCIAL COOKING APPLIANCES BY UNDERWRITER'S LABORATORIES IN ACCORDANCE WITH NFPA 96 AND UL 710 STANDARDS. U.L. FILE #: MH18803 col HOOD TEMPERATURE SENSOR DETAIL HOOD TEMPERATURE SENSOR _ _ _ _ TO T TERMINALSIN / TOP OF H00 _ _ _-�_ THE HOOD T (� OL PANEL TEMPERATURE SENSOR TO BE PLACED IN THE y (SEE AM) (SEECONDIAGR lig---- GREASE EXHAUST HOOD TO ACTIVATE THE EXHAUST FAN CIRCUIT - STSTEM IS SET ® EXHAUST ® 7 115V 1 PHASE EXHA 5�T FAN CONTINUES TO RUN UNDER FINIS SI'�TEM =ff - CONTACTOR I 20 AMP BREAKER - r No I No, YELLOWAPPLIANCE I NC (N RMALLY CLOSED) TO BE USED FOR AUTOMATICALLY ACTIVATE THE EXHAUST FAN --� CONTACTORS. WHENEVER COOKING OPERATIONS OCCUR. THE TEMPERATURE NOI (NORMALLY OPEN) TO BE USED FOR ACTIVATION OF THE EXHAUST FAN SHALL SENSOR HORNS, STROBES, SHUNT TRIPS, ETC. T C OCCUR THROUGH AN INTERLOCK WITH THE Com- - -I NOTE a------- I COOKING APPLIANCES, BY MEANS OF HEAT r EXHAUST FAN #1 Nc IV NC ----------------- I- -No T NO METHODS. 115V 1 PHASE Noce a: T NO T T 4 0.25 HP 5.8 AMPS M -WN - - -TO HOOD SwcH- - - - - - - - - -1 ® 5 ® RED - - -FROM Hoop SWITCH- - - - -. ®5 ® ® I ® 14 MUA FAN CIRCUIT - ® MUA FAN T 15 ® 115V 1 PHASE i WHO/ODFI CH Lar ®1s ® CONTACTOR I 20 AMP BREAKER I TN ® N T FFffE - - - - PILOT GRWND- J ® N ® W 1UA FAN #1 15V 1 PHASE 0.25 HP 5.8 AMPS t_ -t - - - - - - - - - - - - - - - - - - - -I A, SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN AREA, B. FIRE MODE REQUIRES EXHAUST FAN TO OPERATE CONTINUALLY AND STOP SUPPLY FAN, C. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED, D. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANYONE OF THE SYSTEMS, E. GAS AND ELECTRICAL EQUIPMENT AND OUTLETS SERVED BY THE HOOD SHALL BE DEACTIVATED IN THE EVENT OF A FIRE SYSTEM ACTUATION PER NFPA 96 10.4 F. ACTUATION OF THE FIRE SYSTEM SHALL SIGNAL THE ALARM SYSTEM SERVING THE AREA OCCUPIED BY THE HOOD PER NFPA96 10.6 MODEL "NDFWM" EXHAUST HOODS ARE U.L. LISTED FOR USE OVER COMMERCIAL COOKING APPLIANCES BY UNDERWRITER'S LABORATORIES IN ACCORDANCE WITH NFPA 96 AND UL 710 STANDARDS. U.L. FILE #: MH18803 col HOOD TEMPERATURE SENSOR DETAIL HOOD TEMPERATURE SENSOR _ _ _ _ TO T TERMINALSIN / TOP OF H00 _ _ _-�_ THE HOOD T (� OL PANEL TEMPERATURE SENSOR TO BE PLACED IN THE y (SEE AM) (SEECONDIAGR lig---- GREASE EXHAUST HOOD TO ACTIVATE THE STSTEM IS SET EXHAUST HOOD SYSTEM PER FLORIDA MICRO MECHANICAL CODE 507.2.1.1 OPERATION. EXHA 5�T FAN CONTINUES TO RUN UNDER FINIS SI'�TEM =ff - WHICH STATES TYPE I HOOD SYSTEMS SHALL COY �Trc----I BE DESIGNED AND INSTALLED TO r No I No, YELLOWAPPLIANCE I NC (N RMALLY CLOSED) TO BE USED FOR AUTOMATICALLY ACTIVATE THE EXHAUST FAN CONTACTORS. WHENEVER COOKING OPERATIONS OCCUR. THE TEMPERATURE NOI (NORMALLY OPEN) TO BE USED FOR ACTIVATION OF THE EXHAUST FAN SHALL SENSOR HORNS, STROBES, SHUNT TRIPS, ETC. T C OCCUR THROUGH AN INTERLOCK WITH THE Com- - -I NOTE a------- T NC COOKING APPLIANCES, BY MEANS OF HEAT --- sF� Nc IV NC SENSORS OR BY MEANS OF OTHER APPROVED I- -No T NO METHODS. -. - - - Noce a: T NO TEMPERATURE SENSOR RELAY MOUNTED WITH AUTO ON TEMP SETPOINT ADJUSTABLE FROM INSIDE THE CONTROL BOX. TS2 WIRED FOR TYPE I HINGED ELECTRICAL ENCLOSURE 18"HX 12'LX 6'D W FIRE STSTEM NOTE 1: IF PANEL IS REMOTE MOUNTED, OR FIRE SYSTEM IS FIELD MOUNTED THEN MICRO MICRO SIIITCR SWITCH WIRES MUST BE FIELD WIRED. CONTACTS V"A STSTEM IS SET MICRO SI EXHA 5�T FAN CONTINUES TO RUN UNDER FINIS SI'�TEM =ff - FIRE CONDITION EVEN WITH HOOD SWITCH COY �Trc----I OFF r No I No, YELLOWAPPLIANCE I NC (N RMALLY CLOSED) TO BE USED FOR CONTACTORS. II NOI (NORMALLY OPEN) TO BE USED FOR I I HORNS, STROBES, SHUNT TRIPS, ETC. T C T Com- - -I NOTE a------- T NC ® --- sF� Nc IV NC I- -No T NO T -. - - - Noce a: T NO T T 4 T M -WN - - -TO HOOD SwcH- - - - - - - - - -1 ® 5 ® RED - - -FROM Hoop SWITCH- - - - -. ®5 ® ® I ® 14 T 15 ® i WHO/ODFI CH Lar ®1s ® I TN ® N T FFffE - - - - PILOT GRWND- J ® N ® W ® N ® �- - - -'--NEPAL- INPUT POWER - - - CONTROL CIRCUIT T L T �- - - - -HoT- - - - - - 120V 1 PHASE ®L ® 20 AMP BREAKER ®L ®T'S ® - - - - - - - r ------- TTS+ ® ---- L_ � TEMP SENSOR L ------J HOOD SENSOR FIRE RELAY 1 NCI JCOIL+ �FIRE RELAY 2 NC2 ® COM1 NO I NCI (2) SPARE DRY CONTACTS ACTIVATED BY FIRE SYSTEM STATE SHOWN IS WITHOUT POWER OR IN FIRE MODE NO LOW VOLTAGE CONNECTIONS WITHIN THE CONTROL PANEL GENERAL NOTES: z UL RANGE HOOD: MATERIAL: 18 GAUGE STAINLESS STEEL CONSTRUCTION ON EXPOSED SURFACES 18 GA. GALV. ON EXH. PLENUM ALL CONTINUOUS EXTERNAL LIQUID TIGHT WELDS, POLISHED. FILTERS UL CLASSIFIED BAFFLE TYPE. SET IN HOOD ® 45 DEGREE ANGLE, INCANDESCENT LIGHT FIXTURES UL LISTED FOR USE IN COMMERCIAL COOKING HOODS. GREASE TRAY BELOW FILTERS WITH REMOVABLE GREASE CONTAINER, LIQUID VOLUME LESS THAN 1 QUART. ALLAN COMPLIANCE WITH NFPA #96 AND LOCAL BUILDING CODES. 2. TYPE I RANGE HOOD EXHAUST DUCTS: MATERIAL: 16 GAUGE GALVANIZED STEEL, CONSTRUCTION ALL CONTINUOUS LIQUID TIGHT EXTERNAL WELDS. DUCT IS CONNECTED BY 1/2" FLANGES FULL WELDED. DUCTS TO SLOPE TOWARD HOOD. CLEANING ACCESS AT CHANGEIN DIRECTION OF DUCT RUN EXCEPT AT HOOD CHANGE - 3. RANGE HOOD SUPPLY DUCTS: MATERIAL: GALVANIZED SHEET METAL GAUGES, HANGING AND REINFORCING PER SMACNA STANDARDS. 4. RANGE HOOD EXHAUST FAN: AS SPECIFIED ON DRAWING AND CONFORMING TO SMOKE AND GREASE - LADEN VAPOR REMOVAL UL LISTED SUBJECT BULLETIN 762 YZHW. 5. RANGE HOOD SUPPLY FAN: AS SPECIFIED ON DRAWINGS AND CONFORMING TO A NATIONAL TESTING AUTHORITY FOR PERFORMANCE CERTIFICATION. TO BE LOCATED A MINIMUM OF 10'-0" HORIZONTALLY OR 3' VERTICALLY BELOW FROM ANY EXHAUST FAN, PLUMBING VENT AND FLUE STACKS. B. ELECTRICAL: ELECTRICAL HOOK UP AND EQUIPMENT SUCH AS MOTOR STARTERS, SWITCHES, CONTROLS AND COMPONENTS OTHER THAN WHAT IS SPECIFICALLY MENTIONED ON DRAWINGS IS BY OTHERS. 7, FIRE ALARM CONNECTIONS: IF PRESENT IN THE BUILDING, ALL FIRE ALARM CONNECTIONS ARE TO BE MADE OUTSIDE OF THE CONTROL PANEL. THERE IS A SPARE MICROSWITCH (DRY CONTACTS) IN THE FIRE SYSTEM CONTROL HEAD THAT IS WIRED TO A 190 JBOX NEARBY THAT WILL ALLOW LOW VOLTAGE CONNECTIONS. 8. FIRE SUPPRESSION SYSTEM: FIRE SUPPRESSION SYSTEM UNDER SEPERATE PERMIT PRIOR TO FINAL INSPECTION. 9. EQUIPMENT SCREENING: ALL ROOF EQUIPMENT TO BE CONCEALED FROM PUBLIC VIEW, IF REQUIRED, IS TO BE FURNISHED BY OWNER/G.C. UNDER SEPARATE PERMIT. 10. COMPLIANCE: SYSTEM TO BE MANUFACTURED AND INSTALLED IN STRICT ACCORDANCE WITH NFPA #96, LOCAL FIRE PREVENTION BUREAU MECH. AND HEALTH DEPT. STANDARDS I 1 1 E [ I . �? �%ONE� L F, F .�� ; • C E SVS •. �', :No 0050003 :cr_ OLU wl { { t 0Oo STATE OF s h-04201. 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 RODNEY L FRITZ, P.E. m" E-MAIL: HOODDEPOT©AOL. COM PH# 800-322-8730 LICENSE #0050003 REVISIONS NUMBER DESCRIPTION DATE HOOD DEPOT I N T' L. I N C. 710 SOUTH POWERLINE RD. #H DEERFIELD BEACH, FL TOASALK ITALIAN ICE AND CREAMERY 209 N FEDERAL HWY. BOYNTON BEACH, FL IN -3925 SCALE: DRAWN BY. CHECK BY. DATE. _j NOTED MAC By.. 01/04/17 TITLE. - MECHANICAL HOOD DRAWING 1 OF 4 FAN TO BE SECURED TO CURB WITH PRE- ENGINEERED HINGES 18 GAUGE GALVANIZED STEEL - CONTINUOUSLY WELDED LIQUID TIGHT ROOF CURB 15 GA. STEEL STRAP WELDED TO CURD AND - WRAPPED AROUND TRUSS FASTEN TO TRUSS WITH (2) 1/4" DIA. WOOD SCREWS ONE IN EACH CORNER TO SECURE ALL FAN CURBS. ABOVE WILL PROVIDE A CONNECTION OF FAN CURB TO ROOF THAT WILL WITHSTAND WIND LOADS OF 170 MPH WITH A SAFETY FACTOR OF AT LEAST FOUR. 36" MIN PER NFPA 96 7.8.2.1 AND FMC 2014 506.3.13.3 12x12x1 NOMINALLY SIZED ALUMINUM MESH INTAKE FILTER EXHAUST FAN ROOF CURB DETAIL (N.T.S) 14.0 "X 14.0"X 12 BUILDING SECTION FAN BASE SECURED WITH #14 SHEETMETAL SCREWS ON FOUR SIDES 0 MAXIMUM OF 12" O.C. & MINIMUM 3 PER SIDE -16 GAUGE GALVANIZED STEEL CURB BASE CAP CONTINUOUSLY WELDED LIQUID TIGHT TO EXHAUST DUCT TO SUPPORT FANIN CASE OF FIRE - GREASE CONTAINER PER NFPA #56 - 16 GAUGE GALVANIZED STEEL EXHAUST DUCT CONTINUOUSLY WELDED LIQUID TIGHT 12 GAG AT SCREWS W/ RUBBER WASHERS CURB 17.0"X 17.0"X30" 1 /2" = 1p -O" THE FOLLOWING ARRANGEMENT WILL PROVIDE A CONNECTION OF FAN TO ROOF CURB THAT WILL WITHSTAND WIND LOADS OF 170 MPH WITH A SAFETY FACTOR OF AT LEAST FOUR. FAN HURRICANE STRAPPING DETAIL WHEN THE FANS ARE SECURED TO THE CURDS AS SHOWN USING THE 1/8" THICK S/S CABLE THE FAN HOUSINGS WILL WITHSTAND WIND LOAD FORCES UP TO 175 MPH; THEREFORE, THEY ARE IN COMPLIANCE WITH FMC 301.15 2014 AND FBC CHAPTER 16 2014 24 GA GALVAIJIZED 1" HI -HATS 22 GA GALVANIZED CAP W/ 1" FLANGE 1" THICK MINERAL WOOL BOARD 22 GA S/S OR GALVANIZED CAP W/ 1'° FLANGE ' Y.000 , 0 00000 00000 00 .0 000 000 000 000. 0011, 0/10 000 uu0 000 000 000 000 000 000 000 000 Y.Y.'0 000 Lo 00 FIRE PROTECTION ASSY. FOR GREASE RATED DUCT ZERO CLEARANCE TO COMBUSTIBLES 16 GA. CONTINUOUS WELDED LIQUID TIGHT EXHAUST DUCT fa7FROM HOOD TO FAN. (RAPPING NOTES: 1. 22 GA GALVANIZED CAP FITS WITHIN 22 GA S/S CAP. MINERAL WOOL IS INSTALLED BETWEEN CAPS, 2, CAPS ARE SPOT WELDED TOGETHER 3. 1" HI -HATS ARE INSTALLED IN FIELD TO PROVIDE 1" AIR SPACE FROM COMBUSTIBLES. MINERAL WOOL DETAIL (N.T.S) 3' CLEARANCE REDUCTION METHOD PER NFPA 96 C ^" Mr' ^r J EXHAUST DUCT -COMBUSTIBLE SPACER 3USTIBLE MATERIAL L. APPROVED FIRE BARRIER WRAP -RAMIC FIBER WRAPPING PROVIDES TO 2 HOUR RATING. CONTINUE RAP FROM HOOD COLLAR TO THE TOP OF THE ROOF CURB. THERMAL CERAMICS "FIRE MASTER" / FASTWRAP+ INSTALLED PER MANUFACTURER'S SPECS SBCCI - REPORT 21.51 ASTME2336 - COMPLIES NFPA95 - COMPLIES IMC - COMPLIES W/ SECTION 506 & 507 EXHAUST DUCT FIRE WRAP DETAIL N.T.S. 3" --IH OOD--� I---3" SEwnON VIEW :SH OR SHEET METAL ZAL WOOL BAT SHEET METAL 3/8"0 BOLTS W/ NUTS AND WASHERS EXISTING WOOD OR 3/8" LAG BOLTS / TRUSSES. MIN 2" LONG. 3/8" NUT AND WASHER ON TOP AND BOTTOM OF 'L' BRACKET 2 1/4" x 1 3/4" x 1/4" 'L' BRACKET I I ALL THREAD ROD ANCHORED TO HOOD AND 'L' BRACKET WITH 3/8"0 NUTS & WASHERS. 1 EL EXISTING WOOD TRUSSES. 3/8"0 BOLTS W/ NUTS AND WASHERS OR 3/8" LAG BOLTS MIN 2" LONG. 2 x 2 x 1/4" ANGLE IRON OR 12 GA. 1 5/8" UNISTRUT I 2 1/4" x 1 3/4" x 1/4" 'L' BRACKET I ALL THREAD ROD ANCHORED TO HOOD AND ANGLE IRON WITH 3/8"0 NUTS & WASHERS. HOOD HANGING DETAIL N.T.S. �'l v r r ID t No. 0050003 Lu STATE OF N 710 SOUTH POWERLINE ROAD CHIEF ENGINEER AV DEERFIELD BEACH, FL. 33442 RODNEY L FRITZ, P.E. E—MAIL: HOODDEPOT©AOL. COM PH# 500-322-5730 LICENSE # 0050003 REVISIONS NUMBER DESCRIPTION DATE HOOD DEPOT I N T' L- I N C. 710 SOUTH POWERLINE RD. #H DEERFIELD BEACH, FL 1,05ALK ITALIAN ICE AND CREAMERY 209 N FEDERAL HWY. BOYNTON BEACH, FL IN -3925 SCALE: DRAWN DY- CHECK DY.• DA TE. NOTED MAC RLF 01/04/17 TITLE.• MECHANICAL HOOD DRAWING 3 OF 4 1/16" S/S CABLE IN 1/2" EMT AND/OR BUCKEYE SHIELDED CABLE TO SRM CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS FOR CABLE IN CONDUIT AND 9" RADIUS TURNS ON SHIELDED CABLE (CONSULT BUCKEYE MANUAL FOR MAXIMUM LENGTHS AND INSTALLATION INSTRUCTIONS) --�— SRM CONTROL BOX—\ I I I 1/16 S/S CABLE IN 1/2" EMT AND/OR BUCKEYE SHIELDED I CABLE TO SRM CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS FOR CABLE IN�I CONDUIT AND 9" RADIUS TURNS ON SHIELDED CABLE (CONSULT BUCKEYE MANUAL FOR MAXIMUM LENGTHS AND I INSTALLATION INSTRUCTIONS) I I I BFR -5 CYLINDER I CLASS "K" FIRE EXTINGUISHER MOUNTED 48" A.F.F FROM TOP I OF EXTINGUISHER AND WITHIN ___--REMOTEI PULL STATION 30' OF HOOD. A PLACARD (INSTALLED ® 48" A.F.F. SHALL BE AFFIXED TO WALL ALONG PATH OF EGRESS SPECIFYING PROPER USE OF K' • e PART# RPS -M THE EXTINGUISHER SUPPLIED BY LAS LOCATION TO BE FIELD VERIFIED OWNER AND INSTALLED PRIOR TO FINAL. EX COLLAR 8" X 8" Iv— I Lr 459 N-1HP N-2HP HOOD #1 FAN SWITCH PANEL 1" 48' e 0'-1" 4'-0" 3 ' II! - CONTROL PANEL --0 0 ELECTRIC - WAFFLE 0 TABLETOP FRYER PRESS 22"X22" 11"X12" HAZARD AREA 21"X16" FTRF �l1PPRFSSI❑N ELEVATI❑N VIEW SCALE: 1/2" = 1'-0" CONTROL PANEL & DOUBLE MICROSWITCH PROVIDED BY HOOD DEPOT. CONTROL PANEL PRE -WIRED TO LIGHT TO FUSIBLE LINKS AND SWITCH, HOOD SWITCH, AND ONE FIRE SYSTEM 3/8"OSCHD. 40 BLACK REMOTE PULL STATION MICROSWITCH. THE CONTROL PANEL IS PRE -WIRED TO IRON SUPPLY LINE SHUTDOWN MUA AND TURN ON EXHAUST IN CASE OF FIRE. ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHERS. THERE IS AN ADDITIONAL SPDT MICROSWITCH (DRY CONTACTS) PRE -WIRED TO THE J -BOX FOR FIRE MX - ALARM ACTIVATION.` FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIANCES AND 1/4" OD COPPER TUBE RECEPTACLES UNDER HOOD, GAS SOLENOID ACTIVATION, VENT PLUG 9 AND ANY OTHER (REQUIREMENTS BY NATIONAL, STATE, OR SRM LOCAL AUTHORITIES HAVING JURISICTIONUSE TERMINALS Y - COITROL NC AND NO IN THE CONTROL PANEL AS REQUIRED. SFR- HIDER XNC/NO IN THE CONTROL PANEL HAVE 115V/1PHASE AND PANEL ARE DEACTIVATEDIACTIVATED (RESPECTIVELY) UPON FIRE SYSTEM ACTUATION' NOTE: IF THERE IS NO BUILDING ALARM IT MAY BE REQUIRED TO PROVIDE A HORN TO BE SOUNDED UPON FIRE SYSTEM ACTUATION. FIRE CABINET/FIRE SYSTEM DETAILS BUCKEYE PARTS LEGEND SYMBOL DESCRIPTION BUCKEYE P/N D APPLIANCE NOZZLE N-1HP, N-1LP N-2HP, N-2LP L PLENUM NOZZLE N-1HP inches I 50IN PERIMETER N-1 LP Flow DUCT NOZZLE Mounting Number 1501N PERIMETER N -2W (cm) DUCT NOZZLE Points • a REMOTE PULL STATION RPS -M BUCKEYE NOZZLE DETAIL BAND COLOR N-1HP N-1LP N-2HP N-2LP N -2W BLUE RED GREEN YELLOW WHITE �© CYLINDER AND VALVE ASSEMBLY DIMENSIONS A B C D Max. Weight MAXIMUM BFR -5: Model inches inches I inches inches I Flow lbs. Mounting Number (cm) (cm) (cm) (cm) Points (kg) Bracket BFR -5 24.8 (63) 1 16.2 (41) 1 (25) 1 13.4 (34) 5 42 lbs. (19) MB -1 CYLINDER AND VALVE ASSEMBLY DIMENSIONS HOOD TEMPERATURE BUCKEYE FIRE SYSTEM HOOD TEMPERATURE SENSOR---_' NOTES UL-300 GENERAL NOTES: FOR PIPING ALLOWANCES AND BALANCES REFERTO - THE SYSTEM INSTALLATION TOP OF MAXIMUM BFR -5: FLOW 5 FLLOWOW POINTS (SEE DIAGRAM) GREASE EXHAUST HOOD TO ACTIVATE THE BUCKEYE TECHNICAL MANUAL-U.L. FILE EX688S. K TO SOUND UPON ACTUATION OF FIRE BFR -10: 10FLOWPOINTS IN KITCHEN AREA. LISTED SHAI CONFORM TO THE REQUIREMENTS OF NFPA-17A&96 AND ALL BFR -16: 3. ALL HOOD PENETRATIONS TO BE WELDED WHENEVER THE FIRE EXTINGUISHING LIQUID TIGHT OR SHALL USE A UL LISTED U LE STATE AN3 LOCAL COOE& WHICH STATES TYPE I HOOD SYSTEMS SHALL BFR -20: 20FLOWPOINTS 20 FLOW POINTS ALL ELECTRIC AND GAS TO ALL EQUIPMENT ELECTRICAL DEVICES INSTALLED IN TYPE I BUCKEYE BFR SCHEDULE HOODS OR DUCTS ARE SPECIFICALLY BFR -5 APPROVED FOR SUCH USE ACTIVATION AUTOMATICALLY ACTIVATE THE EXHAUST FAN SYSTEM TO HAVE REMOTE PULL STATION SINGLE HAZARD AREA SHALL BE ARRANGED FOR MANUAL MEANS OF ACTUATION AND TANK NOZZLE APPLICATION COVERAGE NOZZLE LIMITATIONS SPECIAL MOTES FOR COVERAGEQTY OCCUR THROUGH AN INTERLOCK WITH THE SECONDARY FIRE SUPPRESSION SYSTEM COOKING APPLIANCES, BY MEANS OF HEAT r N-1LP t DUCT (50") 50" PERIMETER _}UNLIMITED CENTER OF DUCT 1 1 1 N-1HP PLENUM MAX. 12' LONG N/A "V" BANK OR SINGLE 1 1 1 N-2HP SINGLE VAT FRYER 20.25" X 24" 24" MIN/ 45" MAX ANYWHERE WITHIN 2 1 2 (drip%oard5 up to 6) PERIMETER TOTAL NOZZLE COUNT 3 TOTAL FLOW POINTS 4 HOOD TEMPERATURE SENSOR DETAIL HOOD TEMPERATURE SENSOR---_' NOTES I. NO 'GALVANIZED PIPE TO BE USED ONLY TO 'T' TERMINALS IN TOP OF H00 _ _ _ —�_ THE HOOD DEPOT %- CONTROL PANEL TEMPERATURE SENSOR TO BE PLACED IN THE (SEE DIAGRAM) GREASE EXHAUST HOOD TO ACTIVATE THE SUPPLY AND EXHAUST FANS ARE TO SOUND UPON ACTUATION OF FIRE INTERLOCKED WITH PILOT -LIGHTED SWITCH EXHAUST HOOD SYSTEM PER FLORIDA IN KITCHEN AREA. PROVIDED BY ELECTRICIAN) MECHANICAL CODE 5072.1.1 OPERATION. 3. ALL HOOD PENETRATIONS TO BE WELDED WHENEVER THE FIRE EXTINGUISHING LIQUID TIGHT OR SHALL USE A UL LISTED SYSTEM IS ACTIVATED (EVEN WHEN HOOD WHICH STATES TYPE I HOOD SYSTEMS SHALL SWITCH IS IN OFF POSITION). 4. ALL MOTORS, LIGHTS AND OTHER ALL ELECTRIC AND GAS TO ALL EQUIPMENT ELECTRICAL DEVICES INSTALLED IN TYPE I BE DESIGNED AND INSTALLED TO HOODS OR DUCTS ARE SPECIFICALLY SHALL SHUT DOWN UPON FIRE SYSTEM APPROVED FOR SUCH USE ACTIVATION AUTOMATICALLY ACTIVATE THE EXHAUST FAN SYSTEM TO HAVE REMOTE PULL STATION SINGLE HAZARD AREA SHALL BE ARRANGED FOR MANUAL MEANS OF ACTUATION AND WHENEVER COOKING OPERATIONS OCCUR. THE FUSIBLE LINKS FOR AUTOMATIC MEANS OF TEMPERATURE ACTUATION PER NFPA 17A ACTIVATION OF THE EXHAUST FAN SHALL SENSOR OCCUR THROUGH AN INTERLOCK WITH THE SECONDARY FIRE SUPPRESSION SYSTEM COOKING APPLIANCES, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. REQUIREMENTS BY ELECTRICAL CONTRACTOR 1. WIRE EACH FAN CIRCUIT FROM CIRCUIT BREAKER TO LINE SIDE OF CONTACTOR IN CONTROL PANEL. 2. WIRE EACH FAN FROM LOAD SIDE OF CONTACTOR IN CONTROL PANEL TO DISCONNECT SWITCHES ON FAN. DISCONNECT SWITCHES PROVIDED ON FANS. 3. WIRE A 120V 20 AMP CONTROL CIRCUIT TO TERMINALS L AND N IN CONTROL PANEL. 4. IF THERE IS NO FIRE ALARM PRESENT IN THE BUILDING THEN WIRE FROM CONTROL PANEL TERMINALS NO AND N TO HORN/STROBE'` DEVICE IN KITCHEN. 120V HORN/STROBE DEVICE TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 5. WIRE FROM CONTROL PANEL TERMINALS NO AND N TO SHUNT TRIP BREAKERS IN CIRCUIT BREAKER PANEL. ALL ELECTRICAL OUTLETS AND APPLIANCES UNDER THE HOOD NEED TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION. SHUNT TRIP BREAKERS PROVIDED BY ELECTRICAL CONTRACTOR. 6. FIRE ALARM CONNECTIONS -IF A FIRE ALARM IS PRESENT IT NEEDS TO BE CONNECTED TO THE SPARE MfCROSWITCH (DRY CONTACTS). WIRES FOR MICROSWITCH ARE LOCATED IN THE 190 JBOX--NEAR THE FI; KSYSTEM CONTROL HEAD. IF A BUILDING FIRE ALARM IS PRESENT A RN/STROBE DEVICE IS NOT - REQUIRED. 7. HEAT SENSORS NEED TO BE WIRED FROM EACH HOOD TO CORRESPONDING TERMINAL BLOCKS IN CONTROL PANEL. 8. WHEN THERE IS NOT A FIRE CABINET BUILT INTO OUR HOOD THE MICRO SWITCH MUST BE WIRED FROM THE FIRE SYSTEM. CONTROL HEAD TO OUR CONTROL PANEL. THE COM WIRE (BLUE) GOES TO TERMINAL C IN OUR PANEL, THE NORMALLY CLOSED WIRE (YELLOW) GOES TO TERMINAL NC IN OUR PANEL AND THE NORMALLY OPEN WIRE (BROWN) GOES TO TERMINAL NO IN CONTROL PANEL. 9. FIRE SYSTEMS IN TYPE I HOODS THAT SHARE A FIRE HAZARD AREA MUST ACTIVATE SIMULTANEOUSLY. GENERAL FIRE SYSTEM NOTES HOOD AND FANS OPERATIONS REVSIONS NOTES I. NO 'GALVANIZED PIPE TO BE USED ONLY NUMBER USE SCHEDULE 40 BLACK IRON PIPE PER FIRE MODE REQUIRES EXHAUST FAN TO NFPA # 17A OPERATE AND SUPPLY FAN STOPS. 2 SYSTEM TO HAVE AUDIBLE/VISUAL DEVICE SUPPLY AND EXHAUST FANS ARE TO SOUND UPON ACTUATION OF FIRE INTERLOCKED WITH PILOT -LIGHTED SWITCH SUPPRESSION SYSTEM. (INSTALLED AND IN KITCHEN AREA. PROVIDED BY ELECTRICIAN) HOOD EXHAUST FANS SHALL OPERATE 3. ALL HOOD PENETRATIONS TO BE WELDED WHENEVER THE FIRE EXTINGUISHING LIQUID TIGHT OR SHALL USE A UL LISTED SYSTEM IS ACTIVATED (EVEN WHEN HOOD SEAL PER NFPA # 17A SWITCH IS IN OFF POSITION). 4. ALL MOTORS, LIGHTS AND OTHER ALL ELECTRIC AND GAS TO ALL EQUIPMENT ELECTRICAL DEVICES INSTALLED IN TYPE I AND RECEPTACLES UNDER THE HOOD HOODS OR DUCTS ARE SPECIFICALLY SHALL SHUT DOWN UPON FIRE SYSTEM APPROVED FOR SUCH USE ACTIVATION 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SYSTEM TO HAVE REMOTE PULL STATION SINGLE HAZARD AREA SHALL BE ARRANGED FOR MANUAL MEANS OF ACTUATION AND FOR SIMULTANEOUS AUTOMATIC OPERATION FUSIBLE LINKS FOR AUTOMATIC MEANS OF UPON ACTIVATION OF ANY ONE OF THE ACTUATION PER NFPA 17A SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. L •'SCE/V No. 0050003 O : STATE OF -Litz •. •• `�� %.A.ONt'�L �.koos 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 RODNEY L FRITZ, P.E. E-MAIL: HOODDEPOT©AOL. COM PH# 800-322-8730 LICENSE # 0050003 REVSIONS HID SERVICE DIVISION 710 S POWERLINE RD #H DEERFIELD BEACH, FL NUMBER DESCI RIP ION DATE J��M5ALK ITALIAN ICE AND CREAMERY 209 N FEDERAL HWY. BOYNTON BEACH, FL IN -3925 SCALE.DRAWN BY. ::ff MACRLF BY.DATE.NOTED 01/04/17 TITLE. FIRE SUPPRESSION SYSTEM 1 OF 2