15-5000�n �0� 00 LOT 5 CODE ANALYSIS: SCOPE OF WORK: INTERIOR: INTERIOR IMPROVEMENT - NON BEARING WALLS INSTALL NEW STOVE & HOOD APPLIANCES STREET ADDRESS: 2311 S. FEDERAL HWY BOYNTON BEACH, FLORIDA CLASSIFICATION OF WORK: ALTERATION - LEVEL 2 CODES USED: 2014 FLORIDA BUILDING CODE 2014 FLORIDA FIRE PREVENTION CODE NFPA 1: FIRE CODE NFPA 101: LIFE SAFETY 2014 FLORIDA ACCESSIBILITY CODE ZONED: C3 - COMMUNITY COMMERCIAL PARCEL ID: 08-43-45-33-03-000-0012 2311 South Federal Highway, Boynton Beach, Florida 33435 CONSTRUCTION CLASSIFICATION: TYPE: IIB - NON COMBUSTABLE FIRE PROTECTION: NON - SPRINKLED OFFICE WALLS - 0 0 CEILING - 0 EXTERIOR WALLS - 0 REQUIRED EXITS: 1 EXITS PROVIDED TABLE 1016.2 MAX. TRAVEL DISTANCE = 75 FEET OCCUPANCY GROUP: BUSINESS GROUP B � PROFESSIONAL SERVICES GROUP F-1 U MODERATE -HAZARD FACTORY FLOOR AREA: OFFICES = 306 S.F. KITCHEN = 240 S.F. = TOTAL AREA = 546 S.F. OCCUPANT LOAD: MAX. FLOOR AREA ALLOWANCE: (TABLE 1004.1.2) BUSINESS AREAS: 100 GROSS/ OCCUPANT TOTAL 3 OCCUPANTS KITCHEN: 200 GROSS / OCCUPANT TOTAL 2 OCCUPANTS ACREAGE PLAT LIMITS — — — 318.99' T.M. MILO PROPERTIES LLC BOYNTON BEACH, FLORIDA ARCHITECTURAL ARQUITECTURA INT'L RICHARD H. HIDALGO PROJECT MANAGER BOCA RATON, FLORIDA EMAIL: ARQDESIGN94@GMAIL.COM TEL: 561-376-8736 JOHN P. STOPPI JR., PE, FL PE 78807 PRINCIPAL ENGINEER EMAIL: JOHN@STOPPIENG.COM GENERAL CONTRACTOR UNITED FORCES, INC. DANIELA AMOROSO PROJECT MANAGER BOCA RATON, FLORIDA EMAIL: AMOROSOD1@GMAIL.COM TEL: 954-461-4002 LEGAL DESCRIPTION: The South 51.15 feet of Lot 1, Crest View, as recorded in Plat Book 23, Page 154, of the Public Records of Palm Beach County, Florida. Less road right of way. SITE PLAN ACREAGE iM Lj FILE COPY permit INO, s _ _ REVIEWED BY Structural 01 Electrical Plumbing p & z fester Nr 0 I E GRAPHIC SCALE 20, FOUND 4" X 4" CONCRETE MONUMENT NO ID L. I U LLJJUU I r UK — ROAD RIGHT OF WAY PER PARCEL 146 OF STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT OF WAY MAP SECTION 9301-205 SHEET 4 OF 10 LAST REVISED 04-24-58 SCALE: 1" = 10'-0" 0; 1rn rl e I I Q) --� -3<0 0 �W = ) (n � �J L 0 = o O V) 0 rR E_ z a 1 M r 00 co M 0 � M M N Z a `o U 0 CD � T a v U V E-4 a� U w Q 0 rR E_ z a I A. -AL 15-285 OF 2 PROJECT-. COMMERCIAL KITCHEN o 0 � 0a N Z � U O = 2 a I Ip m M W W J W Z 3: w 0O of Z O U Q J of W d VI C a W Q 11 I A. -AL 15-285 OF 2 PROJECT-. COMMERCIAL KITCHEN EXIT SIGNS: I. EXIT SIGNS ARE NOT REQUIRED IN ROOMS OR AREAS THAT REQUIRE ONLY ONE EXIT 'OR EXIT ACCESS. 2. MAIN EXTERIOR EXIT DOORS OR GATES THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS NEED NOT HAVE .EXIT SIGNS. - 3-5/8" METAL STUD (18 GA.)@ 16" 0/C 2"X .4" WOOD 3,E13ER 5/8" DRYWALL EXIa AHU 44" 44"� F_ --r. 50" L SYMBOL �Vr or DESCRIPTION 2 EXIT PROVIDED I OFFiICE �\ -1 r FLUORESCENT RECESSED FIXTURE MAX. TRAVEL DISTANCE 200 FT. W/O SPRINKLER SYSTEM EXIa AHU 44" 44"� F_ --r. 50" L ALL LIGHTING 4 RECEPTACLES ARE EXISTING, NO ADDITIONAL ELECTRICAL DEVICES WILL BE ADDED ELECTRICAL PLAN SUPPORT FOR PLUMBING FIXTURES & CABINETS: STUD WALL SUPPORTING PLUMBING FIXTURES & CABINETS SHALL BE CONSTRUCTED USING STEEL STUDS OF NOT LESS THAN 20ga W/ A MIN. EFFECTIVE MOMENT OF INERTIA EQUAL TO 0.864 in4. WALL SHALL BE CONNECTED TOP & BOTTOM TO PREVENT END ROTATION OR DISPLACEMENT. A HORIZ MEMBER SHALL BE SECURELY FASTENED TO NOT LESS THAN 2 STUDS FOR THE ATTACHMENT OF WALL HUNG FIXTURES. STEEL STUDS SHALL COMPLY WITH 2004 FBC SECTION 2510.5.1 SUCH STUDS SHALL BE RIGIDLY CONNECTED TOP AND BOTTOM TO PREVENT SIGNIFICANT END ROTATION OR DISPLACEMENT. AS PER FBC 2510.8.1.2. A HORIZONTAL MEMBER SECURELY FASTENED TO NOT LESS THAN TWO STUDS SHALL BE INSTALLED FOR THE ATTCHEMENT OF EACH WALL HANG PLUMBING FIXTURE. AS PER FBC 2510.5.13. BACKING FOR TOILET PARTITIONS, GRAB BARS. AND ACCESSORIES: PROVIDE 2x BLOCKING INSDE PARTITIONS AS REQUIRED FOR ATTACHMENT OF ALL WALL HUNG ITEMS, (SEE ELEVATIONS FOR HEIGHTS). ALL WOOD BLOCKING SHALL COMPLY WITH CURRENT FIRECODE. 50" AREA CALCULA-"IONS OFFICE SPACE AIR CONDITIONED AREA 306 S.F. KITCHEN PREP ROOM A/C AREA TOTAL UNDER ROOF UPBLAST EXHAUST FAN ROOF FLASHING DUCT SUPPORT STRAPS EXISTING ROOF TRUSSES j� 8" DIA., 16 GA. / METAL DUCT EXHAUST VENT DETAIL SCALE: 1/4" = 1'-0" REFLECTED CEILING LEGEND SYMBOL DESCRIPTION I'ow DESCRIPTION 2 EXIT PROVIDED EXISTING (RELOCATED) 24"x48" GRID MOUNTED (4L) EXISTING (RELOCATED) 24"x48" GRID MOUNTED (4L) TRAVEL DISTANCE FLUORESCENT RECESSED FIXTURE MAX. TRAVEL DISTANCE 200 FT. W/O SPRINKLER SYSTEM FLUORESCENT RECESSED FIXTURE CONSTANTLY LITE STORIES W/ ONE EXIT MAX. OCCUPANTS PER FLOOR AND TRAVEL DISTANCE L-- —► EXISTING (RELOCATED) 24"x24" GRID MOUNTED A/C SUPPLY TABLE 1021.2 A/C RETURN GRILL (EXISTING) A / 2. EXIT LIGHTING AND EMERGENCY LIGHTING ARE PROVIDED AS REQUIRED PER FBC 1006. SURFACE MOUNT EMERGENCY E3 SURFACE MOUNT EMERGENCY LIGHT W/ LIGHT W/ 90 MIN. BATT. BACKUP 90 MIN. BATT. BACKUP -10r ��� rL WALL/CLG. MOUNT EXIT LIGHT EXHAUST FAN �r KITCHEN j 1 O BACK-UP AND WIRED TO LIGHTING CIRCUIT AHEAD OF ANY SWITCHES. Z'Z z EXISTING MULTI - z IL -11 COMPARTMENT SINK 50„�C PROVIDE UNDER SINK ua:z I_ < W GREASE TRAP W/ A W IL ALL LIGHTING 4 RECEPTACLES ARE EXISTING, NO ADDITIONAL ELECTRICAL DEVICES WILL BE ADDED ELECTRICAL PLAN SUPPORT FOR PLUMBING FIXTURES & CABINETS: STUD WALL SUPPORTING PLUMBING FIXTURES & CABINETS SHALL BE CONSTRUCTED USING STEEL STUDS OF NOT LESS THAN 20ga W/ A MIN. EFFECTIVE MOMENT OF INERTIA EQUAL TO 0.864 in4. WALL SHALL BE CONNECTED TOP & BOTTOM TO PREVENT END ROTATION OR DISPLACEMENT. A HORIZ MEMBER SHALL BE SECURELY FASTENED TO NOT LESS THAN 2 STUDS FOR THE ATTACHMENT OF WALL HUNG FIXTURES. STEEL STUDS SHALL COMPLY WITH 2004 FBC SECTION 2510.5.1 SUCH STUDS SHALL BE RIGIDLY CONNECTED TOP AND BOTTOM TO PREVENT SIGNIFICANT END ROTATION OR DISPLACEMENT. AS PER FBC 2510.8.1.2. A HORIZONTAL MEMBER SECURELY FASTENED TO NOT LESS THAN TWO STUDS SHALL BE INSTALLED FOR THE ATTCHEMENT OF EACH WALL HANG PLUMBING FIXTURE. AS PER FBC 2510.5.13. BACKING FOR TOILET PARTITIONS, GRAB BARS. AND ACCESSORIES: PROVIDE 2x BLOCKING INSDE PARTITIONS AS REQUIRED FOR ATTACHMENT OF ALL WALL HUNG ITEMS, (SEE ELEVATIONS FOR HEIGHTS). ALL WOOD BLOCKING SHALL COMPLY WITH CURRENT FIRECODE. 50" AREA CALCULA-"IONS OFFICE SPACE AIR CONDITIONED AREA 306 S.F. KITCHEN PREP ROOM A/C AREA TOTAL UNDER ROOF UPBLAST EXHAUST FAN ROOF FLASHING DUCT SUPPORT STRAPS EXISTING ROOF TRUSSES j� 8" DIA., 16 GA. / METAL DUCT EXHAUST VENT DETAIL SCALE: 1/4" = 1'-0" REFLECTED CEILING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION 2 EXIT PROVIDED EXISTING (RELOCATED) 24"x48" GRID MOUNTED (4L) EXISTING (RELOCATED) 24"x48" GRID MOUNTED (4L) TRAVEL DISTANCE FLUORESCENT RECESSED FIXTURE MAX. TRAVEL DISTANCE 200 FT. W/O SPRINKLER SYSTEM FLUORESCENT RECESSED FIXTURE CONSTANTLY LITE STORIES W/ ONE EXIT MAX. OCCUPANTS PER FLOOR AND TRAVEL DISTANCE EXISTING (RELOCATED) 24"x24" GRID MOUNTED —► EXISTING (RELOCATED) 24"x24" GRID MOUNTED A/C SUPPLY TABLE 1021.2 A/C RETURN GRILL (EXISTING) GRILL (EXISTING) i 2. EXIT LIGHTING AND EMERGENCY LIGHTING ARE PROVIDED AS REQUIRED PER FBC 1006. SURFACE MOUNT EMERGENCY E3 SURFACE MOUNT EMERGENCY LIGHT W/ LIGHT W/ 90 MIN. BATT. BACKUP 90 MIN. BATT. BACKUP (COMBO LIGHT W/EXIT SIGN) i i rL WALL/CLG. MOUNT EXIT LIGHT EXHAUST FAN TO BE EQUIPT WITH 90 MINUTE BATTERY j O BACK-UP AND WIRED TO LIGHTING CIRCUIT AHEAD OF ANY SWITCHES. NOTES: 1. ALL SYMBOLS MAY NOT BE APPLICABLE. SCALE: N.T.S. CONSTRUCTION NOTES: 240 S.F. I 546 S.F. EXISTING STAINLESS STEEL WALL PANEL * BACK SPLASH ALL EXTERIOR $ INTERIOR WALLS, WINDOWS AND DOORS, BATHROOM FIXTURES ARE ALL EXISTING AND WILL NOT BE ALTERED. 1. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES. 2. CONSULTANTS DRAWINGS ARE SUPPLEMENTAL TO THE ARCHITECTURAL DRAWINGS. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CROSS CHECK WITH ARCHITECTURAL DRAWINGS PRIOR TO THE ORDERING/ INSTALLATION OF ANY MECHANICAL, PLUMBING, AND ELECTRICAL WORK. ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND THE CONSULTING ENGINEERS DRAWINGS SHALL BE BROUGHT TO THE DESIGNERS ATTENTION FOR IMMEDIATE CLARIFICATION. 3. ALL DIMENSIONS ARE TO FACE OF FINISHED MATERIAL (GYP.BD., LAMINATE, ETC.) UNLESS OTHERWISE NOTED. USE WRITTEN DIMENSIONS DO NOT SCALE DRAWINGS. 4. EXISTING DEMISING PARTITIONS ARE TO REMAIN AND MUST REMAIN ONE HOUR RATED AS PER U465. G.C. TO REPAIR DEMISING WALLS AFTER DEMOLITION TO SATISFY FIRE RATINGS. 5. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN SPECIFICATIONS OR INSTRUCTIONS. 6. THE GENERAL CONTRACTOR SHALL PAY ALL FEES, LICENSES, PERMITS, AND INSPECTIONS REQUIRED FOR PROPER EXECUTION OF THE WORK. 7. THE GENERAL CONTRACTOR SHALL PERSONALLY SUPERVISE AND DIRECT THE WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION AND/OR INSTALLATION METHODS, MEANS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATION OF ALL PORTIONS OF THE WORK. 8. CUTTING AND PATCHING: WHERE EXISTING CONDITIONS ARE CUT OR DISTURBED TO PERMIT NEW CONSTRUCTION AND/ OR INSTALLATION, MATCH AND PATCH EXISTING DISTURBED CONSTRUCTION/FINISH. 9. UNLESS NOTED OTHERWISE, THE SUBCONTRACTORS SHALL PROVIDE AND PAY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY, TRANSPORTATION, PERMITS AND OTHER SERVICES AND FACILITIES NECESSARY FOR PROPER AND TIMELY EXECUTION OF THE WORK. 10. THE SUBCONTRACTOR WARRANTS TO THE OWNER AND TO THE ARCHITECT THAT ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THE CONTRACT ARE NEW UNLESS OTHERWISE SPECIFIED, AND THAT ALL WORKS WILL BE AS SPECIFIED AND FREE OF DEFECTS. 11. THE SUBCONTRACTORS SHALL GUARANTEE ALL WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF WRITTEN SUBSTANTIAL COMPLETION. 12. ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE LANDLORD. 13. ALL BLOCKING INSIDE WALLS TO BE FIRE RETARDANT TREATED OR NON COMBUSTIBLE :XPAUST NOTES: XHAUST RATE = 300 CFM/FT 4 FT.= 1200 CFM XHAUST FAN TO PULL 1200 CFM XHAUST DUCT SHALL BE 8"x8" 4 SIZE, 16" GAGE. IOOD SHALL OVERHANG COOKING RANGE PURFACE BY A LEAST 6" ON ALL SIDES, 'HE VERTICAL DISTANCE BETWEEN THE IOOD AND THE COOKING SURFACE SHALL SE, AT MOST, 4 FEET. IVAC SYSTEM SHALL INTERLOCK WITH :XHAUST SYSTEM TO PROVIDE 1200 CFM >F MAKE UP AIR WHEN EXHAUST SYSTEM >PERATES OR 1200 CFM SHALL BE ADDED 'O MAKE UP AIR DESIGN. >RY CHEMICAL FIRE SUPPRESSION SYSTEM >HALL BE PROVIDED PER NFPA 17. LISTING V4ATER HEATER ■ OCCUPANCY TYPE: BUSINESS NUMBER OF EXITS 2 EXIT PROVIDED EXIT ACCESS :W GAS BURNERS W/ TRAVEL DISTANCE MAX. TRAVEL DISTANCE 200 FT. W/O SPRINKLER SYSTEM !) OVENS STORIES W/ ONE EXIT MAX. OCCUPANTS PER FLOOR AND TRAVEL DISTANCE TRAVEL DISTANCE =V4 BACK SHELF HOOD TABLE 1021.2 1. EXISTING BUILDING DOES NOT HAVE OPERATING SPRINKLER SYSTEM. 2. EXIT LIGHTING AND EMERGENCY LIGHTING ARE PROVIDED AS REQUIRED PER FBC 1006. 3. FIRE EXTINGUISHERS REQUIRED (PER F.B.C. 906.3) AND PROVIDED. E3 T'PE I HOOD W/ RE SUPPRESSION rL (STEM LOCATION OF EXISTING O FLOOR DRAIN Z'Z z EXISTING MULTI - z IL -11 COMPARTMENT SINK PROVIDE UNDER SINK ua:z I_ < W GREASE TRAP W/ A W IL GPM RATING 20 EXISTING STAINLESS STEEL WALL PANEL 4 BACK SPLASH SCALE: 1/4" = 1'-0" 202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS: ALTERATION THAT EFFECTS OR COULD AFFECT THE USABILITY OF OR ACCESS TO AN AREA CONTAINING A PRIMARY FUNCTION SHALL BE MADE SO AS TO ENSURE THAT, TO THE MAXIMUM EXTENT FEASABLE, THE PATH OF TRAVEL TO THE ALTERED AREA ARE READILY ACCESSIBLE TO AND USABLE BY INDIVIDUALS WITH DISABILITIES, UNLESS SUCH ALTERATIONS AREA DISPROPORTIONATE TO THE OVERALL ALTERATIONS IN COST. 404.2.5 THRESHOLDS: THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE Y2" HIGH MAX. EXISTING OR ALTERED THRESHOLDS 3/4" HIGH MAXIMUM THAT HAVE A BEVELED EDGE ON EACH SIDE WITH A SLOPE NOT STEEPER THAN 1:2, IS AN EXCEPTION. LIFE SAFETY LEGEND FE LOCATION OF EXISTING FIRE EXTINGUISHER TRAVEL DISTANCE OCCUPANCY TYPE: BUSINESS NUMBER OF EXITS 2 EXIT PROVIDED EXIT ACCESS TRAVEL DISTANCE MAX. TRAVEL DISTANCE 200 FT. W/O SPRINKLER SYSTEM TABLE 1016.2 STORIES W/ ONE EXIT MAX. OCCUPANTS PER FLOOR AND TRAVEL DISTANCE TRAVEL DISTANCE OCCUPANCY F. MAX. 49 OCCUPANTS & 75' OF TRAVEL TABLE 1021.2 1. EXISTING BUILDING DOES NOT HAVE OPERATING SPRINKLER SYSTEM. 2. EXIT LIGHTING AND EMERGENCY LIGHTING ARE PROVIDED AS REQUIRED PER FBC 1006. 3. FIRE EXTINGUISHERS REQUIRED (PER F.B.C. 906.3) AND PROVIDED. 4. CONTRACTOR TO FIELD VERIFY LOCATION OF FIRE EXTINGUISHERS. a •,, z o 15-285 OF 2 PROJECT: COMMERCIAL KITCHEN ( o W No 788€ 7 .. 03 STATE OF ,` » 0 1