Loading...
O80-02ORDINANCE NO. 80- ~, AN ORDINANCE OF THE CITY OF BOYNTON BEACH, FLORIDA AMENDING SECTION 9-36. (SCHEDULE OF PERMIT FEES)., OF THE CODIFIED ORDINANCES OF THE CITY OF BOYNTON BEACH, FLORIDA_, PROVID- ING FOR SAVINGS CLAUSE, REPEALING PROVISION, AN EFFECTIVE DATE AND FOR OTHER PURPOSES. BE IT OP~AINED BY THE CITY COUNCIL OF THE CITY OF BOYNTON BEACH, FLORIDA: Section 1. Section 9-36 (Schedule of Permit Fees) of the Codified Ordinances of the City of Boynton Beach, Florida, be amended to read as' follows: ELECTRIEAL PERMIT FEE' SEHEDULE ALL NEW CONSTRUCTION The master electrical permit fee for a SINGLE BUILDING (as per sp'ecilfications & plans) shall be as follows: AMPERE RATING OF 208V ' 'SERVICE CONDUCTOP~9 SIt{GLE PHASE 140V3~ 480V3_~ III. 0 - !00 20~00 30.00 40.00 101 - 200 50.00 75.00 100.00 201 - 400 90.00 135.00 180.00 401 - 600 150.00 225.00 300.00 601 - 800 350,00 525.00 700.00 801 - 1000 550.00 875.00 1100,00 1001 - 1200 750,00 1125.00 1500,~0 1201 - 1400 9.50.00 1425.00 1900.00 1401 - 1600 1150.00 1725,00 2300.00 1601 - 1800 1350.00 2025.00 2700~00 1801 - 2000 1550.00 2325.00 3100..00 For building shell and meter center only that does not include wiring of individual units, the oermit fee' Shall be 1/2 of the above schedule. The subsequent permit fees £or individual units shall conform with the original sChedule. For every ampere over 2000 an additional charge will be computed as follows: $20.00 for each 100 amps above 2000 single phase. $30.00 for each 100 ~Vs above 2000 if 240V30. $40.00 for each 100 amps above. 2000 if 480V3~, II. TF2iPO~A2ty Sf2IVICE (a) 100 ampere inclusive ......... $ 7.'50 (b) each additional 100 ampere.., ~ , . , ,$ 2'~00 CHA~NGE OF SERVICE & PANEL (~00 ~ere inclusive) .$10.00 Each additional 100 ampere ............. $ 2.00 (Also covers minor electric) Does not cover wiring for swhnning pool. IV. REMODELING AND/OR ADDITIONAL ~arf~ING Conmercial -minimtm~ electric permit for conmercial wilI be $15.00 per tenancy (1 to 10 outlets). For every outlet over 10, an additional $1.00 per outlet shall be charged in'addition to the minlmmn permit. Residential- minimum electric permit for residential will be $I0.00 per tenancy (1 to !0 outlets). For every outlet over 10 an additional $0.50 per outlet shall be charged in addition to the minimu~ permit. 2. SWIMMING POOLS ~Residential oackage unit (transformer, pump., light, grounding & -switches .................. $16.00 3. MOTORS (Conmercial) (a) 1 H.P. or less ................. $ 2.00 (b) Over 1 H.P. thru 3 H.P .............. $ 3.00 (c) Over 3 H.P. thru 5 H.P ........... $ 5.00 (d) Over 5 H.P. thru 10 H.P., ~1'00 per total H.P. (e) Over 10 H.P. $t0.00 plus $0.50 oer additional H.P. 4. MALTILNES (Conmercial) (a) X-ray - portable ................. $ 5.00 CO) X-ray - stationary ................. $10.00 (c) Diathermic and electronic outlet ......... $ 2.00 5. Gt~TORS & TRANSFOP~ERS (conmercial) (a) Each generator or transformer 5KVA or less .... $ 3.00 (b) " " " " over 5KVA thru 10KVA . $ 5.00 (c) " " " " over 10KVA thru 15 KVA. $ 8.00 (d) " " " " over 15KVA thru20KVA. $10.00 (e) " " " " over 20KVA thru 25 KVA. $12.00 (f) " " " " over 25KVA thru 30 KVA. $18.00 (g) " " " " over 30KVA, $18.00 plus $0.50 per additional KVA 6. B~3D~ MACHINES (conmercial) (a) 25 anl0ere or less ................ $ 3.00 (b) over 25 ampere thru50 ampere .......... $ 4.00 (~) over 50 ampere, $5.00 plus $1.00 for each additional 50 ampere or fraction thereof 7, CEILING ~_AT (Comnercial) (a) First 5 ~ .................... $ 5.00 (b) Each additional KW ............... $ .50 8. HEATERS FOR AIR CONDITIONING UNITS (Commercial) (a) First 5 K%J ................... $ 5.00 (b) Each additional KW ............... $ .50 9. DUCT HEA~ (Conmercial) (a) First 5 ~ ................... $ 5.00 Co) Each additional Kt? ............... $ .50 -2- 10. BITS DUCT INCLUDING ~ ~ TAPS FOR. MOTORS, ETC. (Comrmrcial) (a) Per lineal foot ................. $ .30 11.FLRE ALARM CABINET (Con~cial) (a) Minimum fee ................... $ 5.00 (b) Each station & bell ................. 50 SMDKE & FIRE DETECTOR (excluding battery powered detectors) (a) Single umit .................. $ 2.00 (b) Additional units ................. 50 13. BURC~AR ALARMS (Co~Lercial) (a) Minimum fee ................... $ 5.00 (b) Each bell station ................ $ .50 14. If~ VOLTAGE I~qtING ...................... $ 5.00 15. PEP~IT FE~ Elevators, Dumbwaiters, Escalators & Moving walP~s ...... $20.00 STATE APPROVED MODUI~kR HOME PEP~.~ITS ............... $20.00 If over six feet away frc~ outlet MINIb~ SIGN PERMITS (including two ballasts or two transformers. $10~00 Additional Ballasts or Transformers .......... $ 1~50 eA. RE!NSPECTION FEE ~ Each reinsoection due to wrong address, x~ork rejected because of faulty construction, work not ready for inspection at time requested, code violations, repairs and corrections not ~ade when inspection is sclh~duled or permises not accesSible for inspector, my be Charged' ~ ................. $10~00 12. IM ADDITION FEES MAY BE DOUBLE FOR ANY WORK CC~MF~ ~ITHOUT A PFi~MIT Section 2. Authority t.o Codify: Specific authority is hereby granted to codify and incorporate this ordinance in the City's existing Code. Section 3~ Separabilit~f~: Each of the provisions of this ordinance zs separable~ including word, clause, p~rase or sentence, and if any portion thereof shall be declared invalid, the remaining portion shall not be affected but shall remain in full force and effect. Section 4. Re.~,pealing Provision-. . All ordinances or parts of ordin- ances in conflict herewith are hereby repealed. Section 5. An Effective Date: .This ordinance shall becc~ effec- tive in the manner and at the time provided by law. -3- First reading this , 1980. 1980. Second, final reading and passage, this ~ day of CITY OF BOYNTON BEACH, FLORIDA A%TEST: ci~z Cle~ ...... (Corp.. Seal) }~layor Vice ~ydr -4-