DRAWINGSSEE FIXTURE/ECU I PMENT 5GHEDULE FOR ABBREVIATED ITEMS STATION DIVIDER COLORS P = PURPLE 6 = &OLD R = RUST GUTTING STATIONS PROVIDE 20 AMP DEDICATED ELECTRICAL SERVICE TO STATION MOUNTED GUADPLEX. "NO SHARING OF NEUTRALS" -ELECTRICAL CONTRACTOR SHALL INSTALL JUNCTION BOX ABOVE GEILIN6. RUN CONTINUOUS METAL GLAD GABLE FROM JUNCTION BOX THROUGH WALL AT 2'-Q" A.F.F., WITH APPROXIMATELY 18" OF WHIP TO CONNECT POWER TO FIXTURE. SEGURE TO STUDS A5 5PEGIFIED BY CODE. TACTILE "EXIT" 516NA6E PER IGG A117.1 (00" A.F.F. WITH &RADE 2 BRAILLE LETTERS. 1. W TO H RATIO BETWEEN 3:5 � I:1 2. STROKE W TO H BETWEEN 1:5 $ 1:10 3. GONTRA5T CHARACTERS 4 SYMBOLS W/ BAGK6ROUND 4. 5AN5 SERIF UPPERCASE CHARACTERS BRAILLE. I. USE CONTRACTED GRADE 2, BRAILLE DOTS SHALL BE 1/10" O.G. IN EACH CELL WITH 2/10 SPACE BETWEEN CELLS. 2. DOTS SHALL BE RAISED 1/40" ABOVE BAGK6ROUND (TYPICAL OF 3 516N5) PROVIDE HARD -WIRE CONNECTION (VIA WHIP) TO STATION -MOUNTED 4-PLEX RECEPTACLE 6.G. SHALL FASTEN FLEXIBLE % CONDUIT TO SIDE OF FIXTURE z WITHIN 12" OF ELECTRICAL BOX IN WALL. C4 AH I P �=A57EN DETA I L N.T.S. OUTLETS FLUSH WITH GE I LIN& -� TILES FOR LED 516NA6E (ONE ON EACH SIDE OF A-27--" ENTRANGE DOOR) A-2cI TVP. JUNCTION BOX ABOVE GEILIN6 FOR EXTERIOR 516N MOUNTED WITHIN 3'-0" OF EXTERIOR 516NA&E AREA. SERVICE OUTLET AND 015GONNEGT ON RTU #1 SHALL BE INDEPENDENTLY MOUNTED. VERIFY WITH LANDLORD FOR EXACT LOGATION. A-25 PRICE 1 BOARD A-2 A-4 THERMOSTAT VERIFY LOG SAIL W/OWNER -\ FMAT - C5WM -71 TZ M i ` D T, JTO I LB R 0 6FFE( 24" r--- --- - -, ,--- -- ---, FLEX 60 11 �l A.F.F. r ( ; ` -- --- -- A.F.F. j/ R \ P `/ 6 leUAICY -15 EXIST. EXIT �-_---' �___-' `� �FA` DBLVA - 0 WALL 6RAPHIG MRD5K(SEE SHEET Al FOR pN ° DF DETAILS) A-13/5 Q� 3 N A-25 GPI A-2224" x 24"- EXI ST_ 4 BRACE WALL TO LOUVER IN STRUCTURE ABOVE RTU #1 WP DOOR Cl �`� �`� �--C-----?cam � i A.F. . rr- I/ \I I/ \I I \I 2 BVAG 3 4 5 --I L-- --- IL L-- ---j L-- -- -- L-- ---j 6RAPHIG 48" A.F.F. GOAT 18' A.F.F. IM 12" -A.F.F. JELOCKERS LEG. PANEL pf:C I 6RP3 1 A-40,42 A-13 A-8 A-17 A-13 A- I'7 A-20 A-21 POVNER PLAN 208\/ LOAD LIGHTING: 3,250 X 125% 180VA REGEPTAGLE5: 5,5 O 00 DEDICATED GIRGUITS: Q,QOO X 100% GOOL1 N6: 13,5CQ X 100% 25% OF LARGEST MOTOR: 6,840 X 2596' TOTAL: 34,635: 208\/ -I-V3 X 1.00 = 16.1 AMPS DEMAND LOAD ANALY515 ALIGN TRACK L16HT WITH OUTSIDE EDGE OF DESK (BOTTOM OF TRACK HEADS AT 7'-0" - 7'-6" A.F.F.) ---\ 4,063 61,C[00 V I 13,3x2 I/4"=1'-0° ELECTRICAL NOTE: I. CONTRACTOR SHALL INSTALL DI5GONNET MEAN5 FOR FLBALLASTED L16HT FIXTURES PER NEC 410.130 2. CONTRACTOR SHALL INSTALL ARG WARNING LABELS ON ALL ELECTRICAL EQUIPMENT PER NEC 110.16 1,-700 TYPE � I RF. ALARM NOTE: MANUF. SPECIFICATION REMARKS QUANTITY Al ALL FIRE ALARM WORK TO BE PERFORMED DAYBRITE DB-2T654L835-4-F5-02F-UNV 54 W LED VARIES BY LANDLORD'5 BASE BUILDIN6 LYTRONIG5 34,635 CONTRACTOR. I a C.'TFUCIA .. NOT!'' I. BOTTOM OF GENERAL OUTLET BOXES 1 SHALL NOT BE LE -55 THAN FIFTEEN INCHES I ABOVE FIN15H FLOOR. 2 2. TOP OF OUTLET BOXES FOR CONTROLS I AND SWITCHE5 SHALL NOT BE MORE THAN GI FORTY-EIGHT INCHES ABOVE FINISH FLOOR. ,JUNO 3. ALL &ROUNDED AND UNGROUNDED TF4o5L CANOPY T -BAR I CONDUCTORS OF A MULTIWIRE CIRCUIT SHALL R37 T -BAR CLIP 2 BE GROUPED FOR IDENTIFICATION. TF924SL PENDANT STEM (VERIFY/� LENGTH) 3 T PENDANT MOUNTED '-O" A.F.F. 4. PER NEC, 210.4(8) EACH MULTIW1RE TF225L MECH. SUPPORT CYLINDER 2 BRANCH CIRCUIT SHALL BE PROVIDED WITH A TI -575-75-131- 75 WATT TRANSFORMER I MEANS THAT WILL SIMULTANEOUSLY 7W LED7XDMRI(b LAMP 6 DISCONNECT ALL UNGROUNDED CONI LIGHTING JUNC) "If RE THE BRANCH AOTR1 T<PEMEFZOENGY R BAGK ROOM SHALL R5525C TRACK HEAD 6 NATE5. 12W LEDWP302N00/20 LAMP 6 LI BE GONNEGTED AHEAD OF A -2Q LOCAL 5WITGHIN6 LIMITER END /14 A-26 O LI6HT5 LEFT ON 24 HOUR5/DAY O EMER6ENGY EXIT L I &HTI N6 BY LANDLORD A-11 OUTLETS FLUSH WITH GEILIN6 TILES FOR LED 516NA67E (ONE ON EACH 51DE OF ENTRANCE DOOR, A-32 JUNCTION BOX ABOVE GEILIN6 FOR FUTURE USE. (2) 5WITGHES TO EACH CONTROL HALF OF SALON 1_I6HTIN6 48" A.F.F. (1) 5WITGH TO GONTROL_TRAE_ = L16HTIN6,(I) 51AIITGHJC�-G�-?�TROL RECESSED CAN LIGHTING 48" A.F.F. A! -::?,I -23 u ■ WO 111'a A-2cf ,a rd F 5 TYPE DESCRIPTION MANUF. SPECIFICATION REMARKS QUANTITY Al 2 x 4 LED. PR15MATIC LEN5E DAYBRITE DB-2T654L835-4-F5-02F-UNV 54 W LED VARIES 2 xx 44 LED. RETROT LYTRONIG5 RF50UQT435 A2 I 2 1 2 I RECE55ED HOU51H6 2 JU-TG2 DOWNLI6HT VARIES JbRLG3-3K-HZW-64 LAMP I JUNO GI LOW VOLTAGE FLEXIBLE TRACK ,JUNO T FbSL FLEX TRACK I TF4o5L CANOPY T -BAR I TF425L PENDANT STEM SUPPORT 2 R37 T -BAR CLIP 2 R3-10 T -BAR ATTACHMENT 2 TF924SL PENDANT STEM (VERIFY/� LENGTH) 3 T PENDANT MOUNTED '-O" A.F.F. TF215L FEED CYLINDER I TF225L MECH. SUPPORT CYLINDER 2 TF3015L TRACK HEAD 6 TI -575-75-131- 75 WATT TRANSFORMER I 6E 7W LED7XDMRI(b LAMP 6 02 LINE VOLTAGE STANDARD TRACI< JUNC) R4NA 4' ALUMINUM TRACK 2 RANH OUTLET BOX FEED COVER 2 R5525C TRACK HEAD 6 6E 12W LEDWP302N00/20 LAMP 6 LI TRACK LIMITER JUNO TGLIWH I CIRCUIT LIMITER m LIMITER END /14 A-26 O LI6HT5 LEFT ON 24 HOUR5/DAY O RECESSED LED L16HTIN& EXITRONIGS (VERIFY W/ SALON OWNER) EM (TYPE B2) L 16HTI NG PLAN O LOW VOLTAGE LI&HTING (T)TE GO O UNDERCUT DOOR 3/4" TO I" FOR AIR RETURN EXITRONIGS -PENDANT MOUNTED © 7'-C" r 7'-6" M WALL 5EN50R WATT STOPPER W5-200 AUTOMATIC OCCUPANCY W/SWITGH VARIES A.F.F. _ - - __- -_ - O3 LINE VOLTAGE L(6HTIN6 (TYPE -02) �-- I COOPER LIGHTING OR EQUAL 120W - 5A @ 120V - URFAGE MOUNTED CENTERED 5 --- - OONE,-GIRGUIT CURRENT LIMITER z OVER MERCHANDISER. VERIFY-_ Z z WITH OWNER EXACT LOGATICI [._ O 6F JUTILI vel I SINK \,) .7 EXIST. PB 'A' REFER TO THE ALL WALL SURFACES IN PUBLIC AREAS SHALL BE FINISHED WITH GYP. BD. PROVIDE ELECTRICAL, PHONE, AND DATA AT RECEPTION DESK 18" A.F.F. 42" A.F.F. A=12,14 EXISTING LANDLORD 5ERVIGE EX15T. METER EX15T. 200A.4 ISGONNI W/ 200 FU5E5 EXIST. 200A./3P, 208V-1 30 5ERVIGE TO SPACE. ELECTRICAL RISER DIAGRAM SCALE: N.T.S. T LIGHT FIXTURE 56HEDULE - VERSION 01/18/16 TYPE DESCRIPTION MANUF. SPECIFICATION REMARKS QUANTITY Al 2 x 4 LED. PR15MATIC LEN5E DAYBRITE DB-2T654L835-4-F5-02F-UNV 54 W LED VARIES 2 xx 44 LED. RETROT LYTRONIG5 RF50UQT435 A2 2 x 2 LED. PRI5MATIG LEN5E PHILIPS 2TG30L835-2-F5-02F-UNV 43.5 W LED VARIES B2 RECE55ED HOU51H6 xNO JU-TG2 DOWNLI6HT VARIES JbRLG3-3K-HZW-64 LAMP LED DOWNLI6HT JUNO GI LOW VOLTAGE FLEXIBLE TRACK ,JUNO T FbSL FLEX TRACK I TF4o5L CANOPY T -BAR I TF425L PENDANT STEM SUPPORT 2 R37 T -BAR CLIP 2 R3-10 T -BAR ATTACHMENT 2 TF924SL PENDANT STEM (VERIFY/� LENGTH) 3 T PENDANT MOUNTED '-O" A.F.F. TF215L FEED CYLINDER I TF225L MECH. SUPPORT CYLINDER 2 TF3015L TRACK HEAD 6 TI -575-75-131- 75 WATT TRANSFORMER I 6E 7W LED7XDMRI(b LAMP 6 02 LINE VOLTAGE STANDARD TRACI< JUNC) R4NA 4' ALUMINUM TRACK 2 RANH OUTLET BOX FEED COVER 2 R5525C TRACK HEAD 6 6E 12W LEDWP302N00/20 LAMP 6 LI TRACK LIMITER JUNO TGLIWH I CIRCUIT LIMITER m LIMITER END JUNO RCLFIIWH TRACK END FEED 1 E EXIT 516N EXITRONIGS VEXUBPWBWH WITH BATTERY BACK-UP VARIES EM EM. FIXTURE EXITRONICS AP259 WITH BATTERY BACK-UP VARIES EXC EM. EXIT COMBO EXITRONIGS VEXU5PW5WHEL90R389 WITH BATTERY BACK-UP VARIES M WALL 5EN50R WATT STOPPER W5-200 AUTOMATIC OCCUPANCY W/SWITGH VARIES 2. AT LOBBY DESK, USE FLOOR OUTLET IF POWER PACK WATT STOPPER I BZ50 1 O 1 360 MOTION yin STOPPER GI -205 GEILIN6 MOUNTED 5EN50R **GREAT CLIPS INC. HAS ESTABLI5HED A PREFERRED VENDOR ARRANGEMENT WITH VILLA L16HTIN6 FOR THE PENDANT, TRACK AND RECESSED DOWN LI6HT5 USED IN THE LOBBY AREA. PLEASE CONTACT VILLA LIGHTING AT 1-800-325-0g63 OR ONLINE AT VILLALI6HTIN6.GOM E V mm I -N 00 C NNO E Em MM>-t�OM p vii N xx 4; '3_Q ON C c a� m a.�'Qa.LiW3 J N Q_ Z t� N W 0 G z a c� z W W Z Z W W DATE ok/26/IG MMTNa 16101 omm 5TAff DRAM STAfF Cts STAfF ,ttttt���Ut�� C •ENG'� �'••\CENA8. No. Z. �• STATE OF ��i F • •; 01 S •L 0•i'• R� No 55978 EXP 2/28/2017 QFIELD CHANGES 8/17/16 BOLT -ON I3KEAKL-K5 r-t\lv=ts,>vrtiv r(.^ i rnz? Zvli i= vv" I. GONTRAGTOR 5HALL GOMFIRM ALL LOCATIONS 4 LOA05 ON EQUIPMENT HAVE AN UPDATED AND CORRECT PRIOR TO IN5TALLIN6 ANY GIRGUIT. PANELBOAD 5GHEDULE IN PANEL PRIOR TO FINAL IN5PEGTION. 2. GONTRAGTOR 5HALL IN5TALL NEMA 3R EQUIPMENT OUT5I0E � NEMA I EQUIPMENT IN510E. 3. 6.G. 5HALL IN5TALL NEW BREAKER5 TO MATCH IN EXI Permit No. - ° REVIEWED BY DA E Structural % Electricals ISM EXIST CON5TRUGTION ® NEW CONSTRUCTION ZS A PHONE/DATA JAGK5 �T THERM05TAT FOURPLEX OUTLET DUPLEX OUTLET 5PEGIAL OUTLET 0 SEATING FD® FLOOR DRAIN DBL DOOR BY LANDLORD EMEReENCY LIGHTING ® EXIT LIGHT -CEILING MOUNT OO JUNCTION BOX �6 LIGHT 5WITGH THREE-WAY LIGHT SWITCH EXHAU5T FAN 5PEAKER5 -VERIFY 0 LOCATION W/ OWNER 360" DIRECTION, EXTENDED RANGE LENS ® POWER PACK FM AUTOMATIC OCCUPANCY W/ WALL 5WITGH ® 2X2 AIR SUPPLY RN 2X2 AIR RETURN 2X4 TUBE! LAY -IN LED FIXTURE V ! Q 2X2 TUBE LAY -IN LED FIXTURE O RE6E55ED LIGHTING e TRACK L16HTIN6 Plumbing Mechanical - w= P&Z Forester t= i re V ! Q IN TRIGA. NO'Ti'� Ponce, ffi€V) (� N I. ELECTRICAL WHIP FOR 5TYL15T STATIONS OtherI,.6,I TO BE MOUNTED AT 33" A.F.F. ELECTRICAL Processed �/ ., W WHIP FOR FLEX STATIONS TO BE MOUNTED U ., AT A.F.F. BOTH WHIPS BE CONNECTED m _ a - 26" TO _ TO STAION MOUNTED FOURPLEX OUTLET, ALL All wark invoiced on this permit shallccnicr SHALL BE OUTLETS Beach Building Code v Itn ca j Rz ! l U OTHER OUTLETS DUPLEX City of Boynton MOUNTED AT 15" A.F.F. UNLE55 NOTED Q OTHERWI5E. O Ld .. Q 2. AT LOBBY DESK, USE FLOOR OUTLET IF U m W ry P055151 F. OTI ERN15E RUN ELECTRICAL THROUGH WALL. z -REFER TO ELEVATIONS AND DETAILS ON Al SHEETS Z z O O 3. VERIFY T HERM05TAT LOCATION WOWNER. 0 ~ 4. LIGHT FIXTURE5 DE516NATED WITH (DSHALL LEFT ON 24 HOUR5/DAY AND SHALL HAVE O (U >- z O BE AN EMERGENCY BATTERY BACKUP. N O Q (VERIFY EXACT FIXTURES WITH OWNER)tZ 5. LIGPLAN LAYOUT 15 APPROXIMATE. VHTING ! N m (i EXACT LOCATION5 WILL VARY BASED ON GRID LAYOUT. 6. RELOCATE EXI5TIN6 LIGHTING WHEN POWER PLAN NECE55ARY. LIG FMNGI PLAN 7. ALL LIGHTS TO HAVE FLAT ACRYLIC DIFFUSERS GENERAL NOTES UNLE55 REQUIRED OTHERWISE BY LANDLORD OR 5ALON OWNER. 8 LIGHT FIXTURES SHALL BE SUPPLIED BY GENERAL CONTRACTOR. 2" WGO 211 3'1 4.. �.....J LAY WG FLEX 2 u DF SAN I TARP SEWER 5AN 1 TAR*' Sr=�SER 1/2 3/4" LAV WATTS LFMMV TEMPERATURE LIMITING DEVIGE SHALL BE INSTALLED AT LAV AND FLEX STATION TO LIMIT TEMPERATURE TO 110 DEGREES MAX. L I M I TER SHALL MEET ASSE 1070 OR GSAB1253 1/2" - WASHING MACHINE LINT TRAP FIL�5'TNP I+r� WH 4"- 4" GONNEGT TO EXISTING SANITARY SEWER. G.G. SHALL VERIFY EXACT LOCATION IN FIELD GONNEGT TO --- IEXISTING GW I STUB ' FD STWD FLEX STATIONS COME' UTIL INSTALLED WITH WATTS i C tI WHA LF288A VACUUM BREAKER. ----------- GOLD WATER I I 1/2" HOT WATER NEW WATER METER IF �®MESTIG 1/+�14T�R REQUIRED. CONFIRM LOGATION $ TYPE W/LANDLORD 3" VTR I 2 Ij t 1 1/2" �i 1 I/2 I t 1 2" 1 1 HAIR FLEX, 3�� I i TRAP i 1 LAV r I 2" WGO 1 I I/2.. i WG 2�� `., 12�� DF •�, 3" `rte 4.. 2„ t 1 4" 3" FD i 1 1/2' 2„ , UTIL u WASHING MACHINE WB LINT TRAP FILTROL 160 SAN 17ARY IS 4 N.T.S. Y T/-1 TY�� r. .. GONNEG Y � EX15 r rNG SANITARY SEWER. G.G. SHA LL- VE: RIFY_EXA T LOGnTION- IN-FIEL0- PLJJMdIN6 f IXiURL' "..�C.1'�I:DUj.iC MAW DIl:8MPTIGN W.g fJJ. x f9X1M TOTAL. WG HANDICAP MARK FIXTURE TYPE HATER CLOSET tU X25 25 d' (FLUSH TANK) LAV LORY GW HN In! CL }UN6 (1) x:2 2.0 U5 UTILITY SINK (1) x 1.5 15 WA5H WASHING ELONGATED COMBINATION -1.28 6.P.F. 1/2" - MACHINE (1) x 4 4.0 FLEX FLEX WATER OL05ET AND TO NOT HAVE MORE THAN 1.28 6.P.F. STATION (2) x 2 4.0 DF DRINKING HANDICAP AMERICAN STANDARD MODEL #0124.024 FOUNTAIN (2) x 0.5 I.O 1-1.4 GPM TOTAL DOME5TIG FIXTURE UNITS 15.0 FIXTURE UNITS 3/4" DOME5TIG GOLD WATER REQUIRED I" 5UPPLIED 0-22 FIXTURE UNITS REQUIRES 5/8' WATER METER SLIP NUT 1/2 BALL VALVE (TYPIGAL) -� WASHER ILET AND FILTER/ HANDLE ASSEMBLY AN"hi.- 1/2 fir WCM FLOOR I a t • d • i DRAIN 5009T 5TRAF NOTE: FIXNRES MAY BE SUBSTITUTED BY AN EQUIVALANT FIXTURE. ILII p p(A n rte NG (Z�X�j- URE SCHEDULE li L�11-111�11L> II V 1!- u u It W �l ALL 5UB5TITUTION5 SHALL BE 5UBMITED FOR APPROVAL. CO MANUFACTURER FIXTURE GONNEGTIONS MARK FIXTURE TYPE REMARKS d' MODEL NO. GW HN In! v Q ry 5RI665-"DALTON°44648,12'R.I. FURN15H WITH CHURCH OPEN k IG HANDICAP ELONGATED COMBINATION -1.28 6.P.F. 1/2" - 5 2"FRONT ❑ SEAT MODEL NO.24b M WATER OL05ET AND TO NOT HAVE MORE THAN 1.28 6.P.F. � ARCHITECT TO SPEC. DOLOR. HANDICAP AMERICAN STANDARD MODEL #0124.024 Q Q O Fi1RN15Fl W1»FLTA 351q -LW WFI GHRF LAV WALLHUN6 FAUCET HOLES ON 4" CENTERS I/2" 1/2" 11/2" I I/2" G-NEGK FAUCET, LEPER HANDLES LAVATORY NOT MORE THAN 22 GALLON5 PER USE ARCHITECT TO SPEC. COLOR aT 05 6PM • 60 PSI O CU TO BE APPROVED BY OLER o =N0. FLOR5TONE PRODUCTS CO, INC. UTIL UTILITY 51NK NOT MORE THAN 22 6ALLON5 PER U5E 1/2" 1/2" 2" 1 1/2" FM UTILITY SINK. FURNI5H WITH DELTA FAUGET5 12133 AT 05 GPM to 60 PSI PROVIDED BY OWLr_R BELVEDERE U5A CORP. MODEL NO. 2100 FURNI514 FLEX SHAMPOO NOT MORE THAN 1.8 6ALLON5 PER U5E V2" 1/2" 2" 1 1/2" WITH DELTA 2131 FAUCET, LEVEL HANDLES WITH HAIR TRAP. JAY R. 5MITH GO. MODEL STATION laM SPACE (N) W GAM • 60 PSI 8 O 50 GALLON, 21 6PH WH WATER 5TATE ENG -50 -PORT (OR EQUAL) I" I - - 5KW 4 240\/ q A EXPANSION THERM-X-TROL ST -5 3/4" - - - TANK RAISED HEADPLU6 POL15H 5.5. HOO WALL GLEANOUT ZURN MODEL #Z-1446 G/W - - - 311 COVER d VANDAL PROOF SGREW STWD WASHING TO BE APPROVED BY OWNER I/2" I/2" 2" I I/2" AGGE5515LE WASHERIDIZYER PER 2013 AN51 111-1 MACHINE DRYER TO BE ELECTRIC DF HI/LO DRINKING FOUNTAIN TO BOWNER APPROVED BY OW 1/2" 1/2" 112" 11/2 11 GONNEGT TO LANDLORD'S 5PEGIFIG GW SUPPLY X GONNEGTION OVERHEAD. WATTS OOa-OT REDUCE PRESSURE LANDLORD'S PRINGIPAL DOUBLE GHEGK PIPING. VALVE ASSEMBLY. BALL OR GATE VALVES. FWW MXOR SEE PLUMBING (= ARCrNTBGTURA- PLANS FOR ALL FOR =F, PIPE SIZES. 5WPE5) ADMAMZ DRAIN rm d 4 zl DRAIN BODY NOTES FLOOaR DRAIN DETAIL 5CA-E 1/2" ter- 3/4" 3/4" TEMPERATURE LIMITING DEVIGE SHALL BE 1, INSTALLED AT LAY AND ` DF FLEX STATION TO LIMIT �� I„ TEMPERATURE TO 110 WATER DEGREES MAX. LIMITER � � � � 3/4" HAMMER CONNECT TO SHALL MEET A55E 1070 ARRESTERS TNG GW OR G5A13125.3 I EXPANSION 3/4" I I" TANK ' 1 WH I/2" I 1/2" 1 1 1 1 I 1 UTIL I . UNION (TPP.) N � TO TENANT'S PLUMBING FIXTURES WATER METER TO BE DRAIN LINE TO BOTH DIRECTLY READ EXTERIOR OF BUILDING (IN &ALLON5) AND HAVE REMOTE READABILITY. I. METERING ASSEMBLY TO BE PROPERLY INSTALLED AND ADEQUATELY SUPPORTED TO ALLOW FOR EASY MAINTENANCE, REPAIR AND REPLAGEMENT. 2. THE DOUBLE GHEGK VALVE ASSEMBLY SHALL BE A55E L15TED 1015 AND SUPPLIED WITH FULL PORT &ATE VALVES. 3. THE METER 4 CHECKS SHALL BE ACGE551BLE FOR MAINTENANCE WITHOUT REMOVING THE DEVICE FROM THE LINE. 4. DOUBLE GHEGK VALVE BACK FLOW PREVENTER SHALL BE THE REDUCE PRESSURE PRINGIPAL TYPE WITH DRAIN LINE TO EXTERIOR OF BUILDING. 5. SHALL BE MOUNTED MINIMUM 12" A.F.F. TO ALLOW FOR DRAINAGE TYPICAL TENANT WATER METER DETAIL N.T.S. t %l >:XTi FOR NAL- 601b f. A5 WASTE TE ARCH DWG5. OR VETIT 1 CLEANOUT Cot�It�Nc I SGReW CLEANOUT T� POLIS 5.5+ 1 AC M COVM WASTE -W V/ I.NMTO5m HOT WATER SUPPLY---, Vt3 BEN? AT aV ( Lw a-allw FIRE RATED NA5HER MACHINE GONGRBTE BOX (WB -U 1/2 BOILER DRAINS WASTE I DRAINA6E 5UMP ^©��I-IO VENT TO TIE 11111--- LI � (n_% J� TO EXISTING VTR - - --- - - 56ALI! NOW T I$ P TO FLOOR DRAIN 1 NEW WATER METER IF REQU I RED. CONFIRM FURNISH METAL DRAIN - WB r- LOCATION I$ TYPE PAN UNDER WATER HEATER AND DRAIN - _ _=_ _-FZ_B/�K--LOW W/LANDLORD TO FLOOR DRAIN PREVENTER. PLUMBING GO1,7,RAGTOP. SHALL ®M ST I G JAI T R R I S =r�ST fo � .Ep.I Try =ppz. N.T.S. 2" TAILPIEGE - 3" DRAIN TO TIE TO 5EWER FINISHED FLOOR Z' no"I am I. 21, 15 HOT WATER SUPPLY -•-.fes IIIIIIIIIIIIIIII COLD WATER SUPPLY VACUUM RELIEF VALVE 1 PROVIDE HEAT TRAP FITTINGS AT WATTS NO. N36 1 INLET AND OUTLET 1 1 1 1 1 FACTORY INSTALLED 1 ASME T& P RELIEF 1 VALVE EXPANSION LOOP r�� ' DIELECTRIC UNION (TYPICAL) PROVIDE APPROVED DRAI PAN BELOW HEATER EXTEND 4"ON ALL SIDES WATER HEATER c I RELIEF VALVE & DRAIN PAN, PIPING DISCHARGE TO FLOOR DRAIN SERVICE DRAIN VALVE-' VNA7r=R HEATER i;�ETA I L N.T.S. LAVATORY ---- OR SINK JR. SMITH MODEL 26gQ AUTOMATIG TRAP PRIMER WATER SAVER TRAP PRIMER, " OR EQUA. FLOOR DRAIN PRIMER TUBE FINISHED 1/2" GOMPRES51ON FLOOR FITTING DEEP SEAL P -TRAP TRAP PRIMER FINISHED WALL -GOLD WATER -E5GUTGHEON 1/2" SOFT "K" COPPER I. THE BIDDER SHALL V151T THE 51TE BEFORE SUBMITTING H15 PROP05AL TO FAMILIARIZE HIM5ELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITION5 THAT MAY AFFECT 5UGH. EXACT LOCATION AND VERIFICATION OF LANDLORD'S PIPING STUBS SHALL BE THE RE5PON51BILtTY OF THE 5UGGESSFUL BIDDER. 2. GONNEGT NEW FIXTURES TO NEW PIPING RUNS PER LOCAL CODES. REFER TO PLUMBING FIXTURE 5GHEDULE FOR TRIM AND AGGE55ORIE5. 3. COORDINATE ALL WORK WITH OTHER TRADES. 4. CONTRACTOR 15 RE5POIIII FOR 5ECURIN6 ALL REQUIRED PERMITS. 5. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND EQUIPMENT. 6. ALL SUPPLY LINES TO BE TYPE 'L' GOPPER WITH I" FIBER6LA55 IN5ULATION. -GOLD WATER 7. ALL WASTE AND VENT LINES TO BE ABS OR PVC, VERIFY WITH LOCAL CODES 8. A MINIMUM OF A 2965LOPE 15 REQUIRED FOR OW LINES -- 5HOGK ARRESTORS MUST BE LOCATED l.'ILi' om IN THIS POSITION WG -TANK TYPE HANDICAPPED WATER GL05ET BY LANDLORD (VERIFY) LAY - WALL MOUNTED HANDICAPPED LAVATORY BY LANDLORD (VERIFY) WCO - WALL CLEANOUT FD - FLOOR DRAIN H5 - HAIR WA5HIN6 SINK BY OWNER WITH VACUUM BREAKER 4 HAIR TRAP FLEX - FLEX STATION BY OWNER UTIL - UTILITY SINK BY OWNER WASHER - WASHER BY OWNER I H - TER HEATER BY OWNER/CONTRACTOR STATE EN6-50-PORT (OR EQUAL) 50 6ALLON, 21 6PH REGOVERY AT 90F. W, 240\/, 10 NB - WASHER BOX WITH CUTOFF VALVES AKD_DP'.A-lN - NOTE: _ HAIR TRAP TO BE 1145TALLED AT SHAMPOO STATION TO PROTECT - - THE MAIN 5ENER LINE. - - - MIN. IS" MAX. 30" MIN. (b" MAX. IS" V"IIIIlA5H I NCS �4ACH I NE 1:)RA I N BOX (A5) E c 0 v 41 � m w 'sco C NNO•g I E m M�M�M49 pryM n�v► �co.r-.E L Nco to V r; % -a x= 4 mto *5 ON Co0 LC4 f m CL...3. J a Z S2 N W 0 z Q z W W z Z5 z W fY W DATE 04/26/16 rr=T Na rola Di5im 5TAFP DRAWN 5TNr CIG14� 5TAFF ,,���R �C • ENt;F� i♦♦♦ •• \CE10 N •� •o. ft N. 8 :-0; STATE OF ;°C: 'opIII, 4J ♦♦♦ss �•0 PONAk- • O•��,,,�. fz�G. 1'b 58978 EXP 2/28/2017 QFIELD CHANGES 8/17/16 CO N d' � W -. Z Q ry DATE 04/26/16 rr=T Na rola Di5im 5TAFP DRAWN 5TNr CIG14� 5TAFF ,,���R �C • ENt;F� i♦♦♦ •• \CE10 N •� •o. ft N. 8 :-0; STATE OF ;°C: 'opIII, 4J ♦♦♦ss �•0 PONAk- • O•��,,,�. fz�G. 1'b 58978 EXP 2/28/2017 QFIELD CHANGES 8/17/16 PLUMBING PLANS PLUMBING RISERS GENERAL NOTES CO N d' � Z Q ry LL_ (n OW w M (� _ � L.L 0 Q Q O w WW m W Z o O CU >- o =N0. U) N m 0 PLUMBING PLANS PLUMBING RISERS GENERAL NOTES 2" HGO -O" DF SAN I TARP 5EHER HATT5 LFMMV TEMPERATURE LIMITING DEVICE SHALL BE INSTALLED AT LAV AND FLEX STATION TO LIMIT TEMPERATURE TO 110 0E51REE5 MAX LIMITER OF 3/4 "- SHALL MEET A55E 10-10 CONNECT TO OR GSAB125.3 EXISTING GH STUB FD 5TNO FLEX STATIONS COME (i UTIL o INSTALLED KITH HATT5 �HHq) LF288A VACUUM BREAKER. J�----------- GOLD WATER 3/4" 111 11 L 1/2" ------ ---- HOT WATER NEN NATER METER IF I:)OMESTI G ^ATER REQUIRED. CONFIRM LOGATION $ TYPE 1/4" =1'-O" H/LANDLORD 3" VTR i 2 11Il 2 1 1/211 i I ,2 I I I HAIR FLEL_ XI � i� 3IL �/�i! I) TRAP I 1 LAV 2" WGO,- I 1/2 "LII NG 12.. OF `, 4..r, 2.. 2" 4' 13" FD ' �-I I/2' I 2 i SANIT R1' R15MR- 77 -- - - - N.T.S. NN r,T- O EXI!5MNG-=-� - 5ANITARY SEVER. G.G. SHAD `! RI FY EXACT L0_ TI ON= N FYELD- - " MARK DOWMPTION W" PA X F4X = TOTAL. H6 HANDICAP d- MARK WATER CLOSET (I) x 25 25 Z (FLUSH TANK) 44 Q � LAV LAVATORY WALL HUNG (I) x 2 2.0 US UTILITY SINK (I) x 15 IS WASH WASHING (I) x 4 4.0 m MACHINE FLEX FLEX STATION (20x 2 4.0 OF DRINKING FOUNTAIN (2) x 05 1.0 11.4 GPM TOTAL DOMESTIC FIXTURE UNITS 15.0 FIXTURE UNITS 3/4" DOMESTIG GOLD WATER REQUIRED I" SUPPLIED 0-22 FIXTURE UNITS RE61UIRE5 5/8" WATER METER SLIP NUT 110 -------- SLIP HASHER 1-1/2" INLET AND OUTLET --- ---- --- ---- iM IM I MM: FILTER 6 O -RING 't FILTER/ HANDLE A55EMBLY No. 1-701 GATGH-AL.L. HAI R TRAF 5TRAINIM n1w WITH FLOOR a d DRAIN SUPPORT 5TIW OWN 5GALE 1/2" �— 3/4' NOTE- FIXTUR`i MAY BE 5UB5TITUTED BY AN EQUIVALANT FIXTURE. n n nn nBI nG FIXTURE SCHEDULEBE 5UBMITED FOR APPROVAL. / u�ll FIXTURE W 1441 L� PLUMBING"' LL �J ALL SUBSTITUTIONS SHALL N MANUFACTURER FIXTURE CONNECTIONS d- MARK FIXTURE TYPE M REMARKS Z 44 Q � O �^ cc) C-'� MODEL NO. GW HW W V to W � BRIGG6-"DALTON"-#46g8,12'R.I. d� o m WRNISH WITFf GI N1RGH OPEN WG HANDICAP ELONGATED COMBINATION -1.28 G,P.F. 1/2" - 3" 2' OUw FRONT SEAT MODEL NO. 2q6 WATER OL05ET AND TO NOT HAVE MORE THAN 1.28 G.P.F. m ARCHITECT TO SPED. DOLOR Z �:: HANDICAP AMERICAN STANDARD MODEL #0124.024 o-- ROW WiDEL.TA 35 -M -LSP NFLGHDF LAV WALLRj% FAUCET HOLES ON 4' (ENTERS 1/2" 1/2' 1 1/2" 1 1/2' G-WCX FAUCET, LEVER HANDLES O LAVATORY NOT MORE THAN 2.2 GALLONS PER USE a to N ARCHITECT TO 5PEG- COLOR, cn AT 05 604 O 60 PBI FLOR5TONE PRODUCT5 GO, INC. TO BE APPROVED BY OWNER 1/2" 2' 1112o FM UTILITY SINK. FURNI5H WITH DELTA FAUCETS UTIL UTILITY SINK NOT MORE THAN 2.2 6ALLON5 PER USE 1/2" 2133 AT 05 6PM • 60 PBI BELVEDERE U5A CORP. MODEL NO. 2100 FURNISH PROVIDED BY OWt�R WITH DELTA FAUCET, LEVEL HANDLES FLEX SHAMPOO NOT MORE THAN I .8 GALLON5 PER USE I/2" i/2" 2" I I/2' WITH HAIR TRAP. TAY R. SMITH CO. MODEL AP STATION PjH SPACE (NJ /20 6PM O 60 PBI 5150 OR 8-160 50 GALLON, 53 GPH STATE 586-520gIFE (OR EQUAL) I" I" - - RECOVERY AT IOOF. NH HATER 15K4, 208V, 30 HEATER EXPANSION THERM-X-TROL 5T-5 3/4" - - - TANK RAISED HEADPLUG POL15H 55. VrIO WALL GLEANOUT ZURN MODEL #Z-1446 CM - - - 3' COVER 4 VANDAL PROOF SCREW 5T40 WAA5IIING TO BE APPROVED BY 0 WNER 1/2" 1/2' 2' 1 1/2" ACCESSIBLE WA5HER/DRYER 201 -I DRYER TO BE ELECTRIC MACHINE HI&O DRINKING FOUNTAIN TO BE APPROVED BY OWNER V2" I/2' OF LANDLORD'S PIPING. rNorm FLOOR SEE PLUMBING (5EE AK-tMTURAL PLANS FOR ALL FOIL ft" PIPE SIZES. w,u5TAB1.E WN tVD a 4 .v 4 J CONNECT TO LANDLORD' SPECIFIC GW SUPPLY GONNEGTION OVERHEAD. WATTS 00 -( REDUCE PRF SH 1 PRI NG I PAL DOUBLE HE( VALVE EMBL BALL OR GA VALV I 4. TO TENANT'S PLUMBING FIXTURES L WATER METER TO BE U DEIN LINE TO UNION (TYP.) 1 BOTH DIRECTLY READ EXTERIOR OF BUILDING (IN GALLONS) AND HAVE REMOTE READABILITY. d DRAM BODY NOTES: I METEi INC A55EMBLY TO BE PROPERLY INSTALLED AND NSE GAUL MA ENjD DETML. 1/2" 1/2 E ALL VALVE i `I 1/2" (TYPICAL) LEX LAV FLEX 5TA 5T`E I NST LED NI TH TT5 L - V ,/' �'' 3/4" AKER. T5 LFMMV % / ,--� I PERATLRE LIMITING D VICE SHALL BE '/ I I TALLED AT LAY AND `\ DF:d LEX STATION TO LIMIT It TEMPERATURE TO 110 \ ` \ I11 HATER CONNECT TO DEGREE5 MAX. LIMITER \ 3/`F HAMMER EXISTING GN SHALL MEE i A55E 1010 \ ARRESTERS STUB OR 05AB 125.3 EXPAN51 ON 3/4" I I it TANK NH 1/2 1/2" I I i UTIL ADEQUATELY SUPPORTED TO ALLOW FOR EASY MAINTENANCE, REPAIR AND REPLACEMENT. 2. THE DOUBLE CHECK VALVE ASSEMBLY SHALL BE A55E LISTED 1015 AND SUPPLIED WITH FULL PORT GATE VALVES. 3. THE METER � CHECKS SHALL BE ACCESSIBLE FOR MAINTENANCE WITHOUT REMOVING THE DEVICE FROM THE LINE. 4. DOUBLE CHECK VALVE BACK FLOW PREVENTER SHALL BE THE REDUCE PRESSURE PRINCIPAL TYPE WITH DRAIN LINE TO EXTERIOR OF BUILDING. 5. SHALL BE MOUNTED MINIMUM 12" A.F.F. TO ALLOW FOR DRAINAGE TYPICAL TENANT WATER METER DETAIL N.T.5. HAY WOO � FOR WALL GOPST A5 WASTE 5EE ARCH DWGS 1 1 OR VERT 1 GLEANOItC I CLEANOUT TIT POU5wD 51 AW 55 COVER O O I WASTE Uft W/ L 5sm TO SIT HOT WATER 5UPPLY— Ve BCS AT ftV OF UNE a4ANOUT FIRE RATED WA5HER MACHINE CONCRETE 13OX (W8-1) I !Ier tT 1/2" BOILER DRAIN5— WA5TE UNE DRAINAGE SUMP— © I -I CLEANOUT D����� O VENT TO TIE— WL � jj d TO EXISTING VTR 5GALE NOW T P TO FLOOR DRAIN , 1 NEN NATER METER IF I 1 WB REQUIRED. CONFIRM FURNI 5H METAL DRAT i't - LOCATION TYPE PAN UNDER WATER N/LANDLORD HEATER AND DRAIN - - - - - = = = - - 'RPZ SALKFLON TO FLOOR DRAIN PREVENTER. PLUMBING CONTRACTOR -SHALL I7®1�F.5TICi VNATF.R RSEM _- -TEST Y0 GERITt Y RPZ- N.T.S. 2" TAILPIEGE — 3" DRAIN TD TIE TO 5EWER FIN15HED FLOOR HOT WATER SUPPLY - COLD WATER SUPPLY VACUUM RELIEF VALVE ROVIDE HEAT TR FITTINGS AT WATTS NO. N36 1 INLET AND OUTLET I 1 1 I 1 FACTORY INSTALLED 1 I ASME T & P RELIEF f i VALVE y- DIELECTRIC UNION I (TYPICAL) PROVIDE APPROVED DRAT PAN BELOW HEATER EXTEND 4"ON ALL SIDES WATER HEATER I C RELIEF VALVE & DRAIN PAN, PIPING DISCHARGE TO FLOOR DRAIN SERVICE DRAIN VALVE- -� ^A7r=R Hr=ATr=R r;�ETA I L N.T.S. LAVATORYM OR SINK -------- J.R. SMITH MODEL 26aQ "AUTOMATIC TRAP PRIMER" NATER SAVER TRAP PRIMER, OR EGUA. \\_� j FLOOR DRAIN PRIMER TUBE FINISHED I/2" COMPRESSION FLOOR FITTING DEEP SEAL P -TRAP GOLD WATER 5HOGK ARRE5TO MUST BE LOCATE IN THI5 P051TION MIN. IS" MAX, 30" MIN. b" MAX. I V 1-1ACHINE 1:)RAIN BOAC (VS5) N.T.S. - FINISHED HALL -GOLD HATER -ESCUTCHEON 1/2" SOFT "K" COPPER TRAP PRI MERE - PLUF�IN6 dL. I. THE BIDDER 5HALL VISIT THE 51TE BEFORE 5UBMITTING HIS PROP05AL TO FAMILIARIZE HIMSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY AFFECT SUCH. EXACT LOCATION AND VERIFICATION OF LANDLORD'S PIPING STUBS SHALL BE THE RESPONSIBILITY OF THE SUCCESSFUL BIDDER. 2. CONNECT NEW FIXTURES TO NEW PIPING RUNS PER LOCAL CODES. REFER TO PLUMBING FIXTURE 56HEDULE FOR TRIM AND AGGE55ORIE5. 3. COORDINATE ALL WORK WITH OTHER TRADES. 4. CONTRACTOR 15 RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS. 5. CONTRACTOR SHALL PROVIDE 5HOP DRAWIN65 FOR ALL FIXTURES AND EGAPMENT. 6. ALL SUPPLY LINES TO BE TYPE 'L' COPPER WITH I" FIBER5LA55 INSULATION. 1. ALL WASTE AND VENT LINES TO BE AB5 OR PVC, VERIFY WITH LOGAL CODES 6. A MINIMUM OF A 2% SLOPE 15 REQUIRED FOR DW LINES R5 D 1.C4'I0 WG - TANK TYPE HANDICAPPED WATER OL05ET BY LANDLORD (VERIFY) LAV - WALL MOUNTED HANDIGAPPED LAVATORY BY LANDLORD (VERIFY) WGO - WALL CLEANOUT FD - FLOOR DRAIN H5 - HAIR WASHING 51NK BY OWNER WITH VACUUM BREAKER 4 HAIR TRAP FLEX - FLEX STATION BY OWNER UTIL - UTILITY 51NK BY OWNER WASHER - 4A5HER BY OWNER DRYER - DRYER BY OWNER WH - WATER HEATER BY OWNER/GONTRAGTOR STATE 586-520c[IFE (OR EQUAL) 50 GALLON, 53 GPH RECOVERY AT IOOF. _ 1504, 208V, 30 WB - WASHER BOX WITH CUTOFF -" V25 -At -110 -DRAIN NOTE: - HAIR TRAP TO BE IN5TAUI .E1- AT -UTILITY STATION _ AND AT 5HAMP00 5TATION TO THE MAIN 5EWER LINE. E o o v Go �m •M IN C> i � f a'�E0 vM�'MVI'® xx m m��a ag ac > c ONC.0 Omc J J iZ Z ry-.. La D a z E La Lu =--- CD Z w cx w (A N am z d- M Z 44 Q � O �^ cc) C-'� J = >- O °O Li to W � d� o m DATE 04/%/* Prom Na 16101 Desla� STAFF DRANN 5TAPP Gtt:%I� NAW 00 �C ENG i� ..... • E< . • \ C E N S • •� •.00 • • No. 58978 � • STATE OF :W - P 41' 's, 0 R � 0. •' v ,� AL REG. NO 58978 AXP 2/28/2017 At:0 8/03/18 PLUME NNG PLANS PLUMBING FUSERS GENERAL NOTES N d- M Z M Q � O (n J = >- � Li to w CL m "1_7 Q LL O Q OUw m Z �:: wzz o-- O o O O =NO a to N m cn PLUME NNG PLANS PLUMBING FUSERS GENERAL NOTES