Loading...
DRAWINGSADJACENT TENANT OCCUPANCY: BUSINESS 'B' AND FACTORY INDUSTRIAL 'F1' f, a RIE xE,I,, t i IEXI'_ -p------I----OFR 10! -Ili III I gt_de F'RO` IDF NE-Vil 0PETV_R FOR EXIST;N-G OV'1 HEAD DOCrz XIST---- -" ---- ---- ' CT RM - -----. 114 I _ -_ 4.51 Exlsr I, iv WAREHOUSE; _ = 101 EXIST r= HALL 1110 SIu 4a �I a_N -- i � - it I *, I 4 !i 105 1M i'% I ; I.; II' ; Ise is I I I UBI tom) 117 •_• Iii ° +4 .. (tet u "o I OFF ;S' -I ° II ICE 114 I '� S _-AAE. 0 . EXIST OFFICE rp IVV 114 ' e v EXIST OFFICE 115 -_-- - --"--L-------- 10! 101i ! I;! �(U) . I ' 31 f PRIVATEIRESTRM 8 I@ @, rQ g I 118 _ - _= � - ----Ii I � 1 i Il EXIST----- ------ - --- - ----- - ------- --------- -------- PO. 3 � I ;I I 1 ADJACENT TENANT OCCUPANCY: BUSINESS 'B' AND FACTORY it INDUSTRIAL 'F7' -8 3 11? e ES II WAREHOUSE ? s _ }20 I i - I I 7 _g ilk' A-' 10-011_ 'd I t N === ---- r L { ADJACENT TENANT II ADJACENT TENANT OCCUPANCY: BUSINESS 'B' OCCUPANCY: BUSINESS 'B' AND \. I AND FACTORY INDUSTRIAL 'F1' FACTORY INDUSTRIAL 'F1' FIRE 59RIWL NOVATION PLAN for UNITS 2104 4 210 1 q f � SCALE: 1/8" = 11-011 SCALE 1/,Sll-ll � FIRE 5PRINKLER RENOVATION,- FLAN LOWER MEZZANINE { � q y � scare: vs° = r_011 scaF iia^.r-o^ !.� I q Y -�-� OYNTONt a T a MAXIMUM PIPE HANGER SPACING PIPE TYPE 3/4- 1' 1 1/4' 1 1/2' 1 2- 2 1/2' 3- 4- 6- 5'-6" 6'-0' 6'-6' Y-0" 8'-O' W-0' 10'-0' N/A N/A CPVC PIPING THRD LT. WALL STEEL N/A 12'-0' 12'-0' 12'-0' 12'-0' 12'-O' N/A N/A N/A STEEL PIPING N/A 12'-0' 12'- 15'-0' 15'- 15'-0' 15'-0' 15'-0' 15'-0' NOTE, STANDPIPES SHALL BE SUPPORTED AT EACH FLOOR USING RISER CLAMPS. ARMOVERS GREATER TWIN 24' SHALL BE SUPPORTED BY A HANGER. ^t ARMOVERS GREATER 7HAN 12" SHALL BE SUPPORTED BY A HANGER WHEN THERE IS A UPPL'INBeam Clamp a� A.T.Rod (Length) Hanger Ring TYPICAL BEAM CLAMP HANGER DETAIL ® SCHEDULE z 1. EXISTING DROP TO BE REMOVED. 2. EXISTING BRANCHUNE. 3.1" ARMOVER.• a 4.1" DROP. 5. NEW FIRE SPRINKLER HEAD Q a SCHEDULE 1 EXISTING BRANCHLINE. 3 2. 1"x 0'-2' SCH 40 NIPPLE 3. 1- ARMOVER * 4. 1" DROP. 5. 14EW FIRE SPRINKLER HEAD 4 _ O T "* ARMOVERS GREATER THAN 24" IN LENGTH SHALL BE SUPPORTED BY A HANGER. TYPICAL ARMOVER DETAIL from PENDENT & UPRIGHT OUTLET SPRINKLER LEGEND SYMBOL TOTAL DESCRIPTION 3 NEW - 1/211 5.6K X W5R CHROME PENDENT w/ 401 2PC DEEP ESCH (ON DROP) 20 EXISTING TO REMAIN 1/211 5.&K X 155°5R CHROME PENDENT w/ 4101 2PC DEEP ESCH 49 EXISTING TO REMAIN 3/4" 8.0K X 1550SR BRASS UPRIGHT ® 19 EXISTING SPRINKLER HEAD TO 5E REMOVED 4 OUTLET PLUGGED TOTAL THIS SHEET 3 TOTAL TH15 J05 3 FACE C SPRINKL FITTINI --CEILING 2 pc. DEEP DME CANOPY SCUCHEON EX15TING 1/211 5-&K 1(o505R CHROME PENDENT TO REMAIN GENERAL OTE5 1. DESIGN 4 INSTALLATION TO BE PERFORMED IN ACCORDANCE I.UITH NFP,4 13 2001 AND LOCAL AUTHORITIES. 2. ALL FIRE SPRINKLER DEV(GES TO F3E UL LISTED AND/OR FM APPROVED. 3. FIRE 5PRINKLER SPACING TO BE PER LIGHT HAZARD OCCUPANCY 225 SF MAX. DESIGNED TO A .10/1500 8QFT for OFFICE AREAS, AND 5ATHROOM5 ORDINARY GROUP I OCCU. 130 8F MAX. DESIGNED TO A .15/1500 SQFT for STORAGE AREAS AND MECH. ROOMS 4. PIPING TO BE (ASTM A-120) A. ALLIED XL FOR 1" THRU 2" OR EQUIL 5, 5CH. 10 FOR 2-1/2" AND LARGER C_ SCH. 80 IF 1/2" OR 3/411 NIPPLE 16 USED. NOTE: NIPPLE CANNOT EXCEED 4" IN LENGTH AND SUPPLY ONLY ONE HEAD PER NFPA 13, 5. FITTINGS A. BLACK GIS CLASS 125 FOR 111 THRU 211. B. GROOVED TYPE FOR 2-1/2" AND LARGER. (o. HANGERS TO BE IN ACCORDANCE WITH NFPA 13 AND LOCAL AUTHOR I T I E5. -I. BALANCE OF EXISTING FIRE SPRINKLER SYSTEM TO REMAIN AS 15 U.N.O. 8, FINSHED SPRINKLERS ARE TO BE INSTALLED WITH INTENTION OF BEING CENTER OF CEILING TILE U.N.O. 9. BROKEN LINES INDICATE EX15TING PIPING AND SOLID LINES INDICATE NEIU PIPING. 10. ARMOVER PIPING IS 111 U.N.O. NO.I DATE I REVISIONS I BY ® 2014 RBK FIRE SYSTEM, INC. RBK FIRE SYSTEM, INC. SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALL COMMON LAZY, STATUTORY AND OTHER RIGHTS, INCLUDING COPYRIGHT. 5YM50L LEGEND CEILING HEIGHT NEW SPRINKLER PIPE EXISTING SPRINKLER PIPE] U m DEMO EXISTING SPRINKLER PIPE Q c_ -4— NEW MECHANICAL TEE (SEE PLAN E U FOR SIZE 4 LOCATION) M 0 p O 0O Q) [01-011 bts ] ELEVATION BELOW TOP of STEEL � o m + U [01-011 ] ELEVATION ABouE FINISHED FLOOR O + (TOS 0'-0") ELEVATION 6 TOP OF STEEL -,— M Q ' 0 7 m IL Q)P 0 A tam 45 4 0 CN y mci °k ; n 2-3116're` (55,6 mm) 1.zk " i kssu"D fl. = DEC 0 12014; Dy ,� SEAL DRAWN BY: ZR CHECKED BY: BR DATE: 7/3/14 SCALE: AS NOTED ' A° AHJ: CITY OF BoyntonOh EXISTING 3/4" B.OK 1555R 51RA55 UPRIGHT JUL2 % CONTRACT, }'X O REMAIN COPY SHEET IUI DING DIVISION F P I o F I